5 - Operation
112
cause risk of contamination and injury from the quick coupler lid being “shot” off when pressurized! If not possible to
fit the lid completely, lubricate the rubber seal and the grip hooks.
5.
Engage the pump and set PTO speed at max. 540 RPM or 1000 RPM (depending on pump model).
6.
Open the TurboFiller lid. Open the TurboDeflector valve and the
TurboFiller suction valve.
7.
Measure the correct amount of powdered chemical and sprinkle it
into the hopper as fast as the transfer device can flush it down. The
TurboFiller suction valve must be open for at least 20 seconds after
the chemical is no longer visible in the hopper in order to
completely empty the transfer hoses into the MainTank.
€
DANGER! If the TurboFiller and the transfer hoses are not
completely emptied, there is a risk of chemicals flowing back into the hopper!
€
DANGER! Always wear face shield and other appropriate personal safety equipment, when filling chemicals.
8.
If the chemical container is empty, it can be rinsed by the “chemical
container cleaning device”. Place the container over the multi-hole
nozzle and push the upper lever to the left of the TurboFiller.
€
DANGER! In order to avoid spray liquid hitting the operator, do
not press the lever unless the multi-hole nozzle is covered by a
container, as spray liquid may otherwise hit the operator!
μ
ATTENTION! The rinsing device uses spray liquid to rinse
containers for concentrated chemicals. Always rinse the chemical
containers with clean water several times, until they are clean before disposal.
9.
Flush the TurboFiller with clean water by shifting to suction from the RinseTank or from an external tank. The TurboFiller
suction valve must be open for at least 20 seconds after the rinse water is no longer visible in the hopper, in order to
completely empty the transfer hoses into the MainTank.
μ
ATTENTION! If the suction SmartValve is not shifted to suction from a clean water supply, the hopper rinsing device
uses spray liquid for rinsing the hopper! Cleaning the TurboFiller must always be done, when the spray job is ended,
and together with cleaning the entire sprayer. A cleaning after the last filling, and before spraying, does not ensure a
clean TurboFiller!
10.
Close the TurboFiller suction valve, when the hopper has been rinsed. Close the lid.
11.
If closed, turn the agitation valve towards “agitation”.
12.
When the spray liquid is well agitated, turn the handle for pressure
SmartValve towards “spraying” position. The agitation continues
during spraying of the crop.
μ
ATTENTION! If foaming is a problem, turn down the agitation.
Содержание NAVIGATOR VPZ
Страница 4: ...1 EU Declaration 4...
Страница 72: ...3 Description 72...
Страница 135: ...6 Maintenance 135 Lubrication Plan Boom Wings 10...
Страница 174: ...6 Maintenance 174...
Страница 182: ...7 Fault Finding 182...
Страница 195: ...8 Technical Specifications 195 Hydraulic Diagrams Hydraulics for Boom of 21 24 Meters...
Страница 196: ...8 Technical Specifications 196 Hydraulics for Boom of 27 28 Meters...
Страница 198: ...8 Technical Specifications 198...
Страница 204: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...