6 - Maintenance
124
Service and Maintenance Intervals
General Info
National or regional laws may require periodic inspection of the sprayers in use. See the following section for more details.
The subsequent periodic service and maintenance work may be carried out by the user. Contact your HARDI dealer if in
doubt. If this work is completed correctly, the sprayer will run efficiently and its lifetime will be prolonged.
When a number of hours are mentioned in this chapter, this means hours of spraying, unless otherwise explained. Operation
hours can be read in the controller in the tractor (see instruction book for controller).
Periodic Inspection
According to EU Directive 2009/128/EC regarding sustainable use of pesticides, all countries in the European Union are
obliged to inspect sprayers used for plant protection. This mandatory inspection also includes your HARDI sprayer.
The condition of the sprayer must be verified. The object of the inspection is to ensure a safe and uniform distribution of
spray liquid on the plants, as well as minimizing leaks into the environment. The inspection on your sprayer may involve
testing the condition of the pump, PTO, tanks, liquid system, measuring components, spray boom, nozzles, agitation of spray
liquid, filters, pipes and hoses.
The inspection and testing is carried out by an authorized person, who is not the owner nor the operator of the sprayer. With
a positive result, a certificate or test sticker will then show that the inspected sprayer is approved for future use. With a
negative result, the faults must be rectified to get the approval.
Check your national rules and guidelines for requirements included in this inspection as well as the interval between
inspections. For more information on how to approach this inspection, please contact your local HARDI dealer.
Tightening Bolts and Nuts
When tightening bolts and nuts as a part of periodic service or due to replacement of spare parts, it is important to apply
the correct torque. This will prevent accidents and prolong the lifetime of the parts included in the bolted joints.
If not otherwise stated in this book, please tighten bolts and nuts using the following torques.
*Exceeding this value results in a great risk of deforming the bolt.
Material: Surface treated steel
Material: Stainless steel
Bolt size
(metric)
Recommended
torque (Nm)
Maximum torque
(Nm)*
Bolt size
(metric)
Recommended
torque (Nm)
Maximum torque
(Nm)*
M4
2.4
3
M4
1.7
2.1
M5
5
6
M5
3.5
4.2
M6
8
10
M6
5.6
7.0
M8
20
25
M8
14
17.5
M10
39
50
M10
27
35
M12
70
85
M12
49
60
M14
112
140
M14
78
98
M16
180
215
M16
126
151
M18
240
305
M18
168
214
M20
350
435
M20
245
305
M22
490
590
M22
343
413
M24
600
750
M24
420
525
M27
976
1100
M27
683
770
M30
1300
1495
M30
910
1047
Содержание MEGA VPZ NK
Страница 1: ...MEGA VPZ Original Instruction book 67050600 110 version 1 10 GB 03 2018 www hardi international com...
Страница 4: ...1 EU Declaration 4...
Страница 10: ...Table of Contents 10...
Страница 42: ...2 Safety Notes 42...
Страница 68: ...3 Description 68...
Страница 118: ...5 Operation 118...
Страница 121: ...6 Maintenance 121 Lubrication Plan Boom Centre Close up of Glide Shoes to be Lubricated...
Страница 122: ...6 Maintenance 122 Lubrication Plan Boom Wings Both boom wings left and right are to be lubricated equally 10...
Страница 172: ...8 Technical Specifications 172...
Страница 176: ...Index 176...
Страница 178: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...