197
8 - Technical specifications
A
PPENDIX
Specifications
Technical Specifications
Do not exceed the specifications below:
•
Storage Temperature: -22° to +176°F (-30°C to +80°C)
•
Operating Temperature: -4° to +158°F (-20°C to +70°C)
•
Operating Input Voltage: 9 –16 V DC
•
Max Current Rating: 7.5 amp
•
Fuse: Blade style (ATO/ATC)
•
Environmental Protection Rating: IP64
•
No Protective Grounding required
•
Use 150V insulation rating for external circuits
±
WARNING! Exceeding these specifications may result in degraded operation and/or damage to the display.
Sprayer Offsets
Standard offsets for common HARDI® sprayers:
μ
ATTENTION! For exact measures it is recommended to measure the specific sprayer/boom combination used.
Rear axle to Application point
Left/Right from Center line
PRESIDIO 2700
84 in
0.00 in
ALPHA 4100
89 in
0.00 in
SARITOR 4000
84 in
0.00 in
SARITOR 5000
84 in
0.00 in
Hitch to Axle
Hitch to Application Point
(Forward/Backward from Hitch)
Left/Right from Center line
RANGER 2000
150 in
204 in
0.00 in
COMMANDER 4500
209 in
307 in
0.00 in
COMMANDER 5500
238 in
339 in
0.00 in
COMMANDER 7000
238 in
339 in
0.00 in
NAVIGATOR 3000
180 in
266 in
0.00 in
NAVIGATOR 3500
180 in
266 in
0.00 in
NAVIGATOR 4000
180 in
266 in
0.00 in
NAVIGATOR 4000 (120’ SPC)
208 in
284 in
0.00 in
NAVIGATOR 6000
215 in
289 in
0.00 in
Содержание HC 9600
Страница 2: ......
Страница 4: ......
Страница 12: ...2 Safety Notes 10...
Страница 32: ...3 Description 30...
Страница 182: ...5 Operation 180...
Страница 184: ...6 Maintenance 182...
Страница 198: ...7 Fault finding 196...
Страница 202: ...8 Technical specifications 200...
Страница 210: ...Index 208...
Страница 211: ......