7 - Menu 3, Calibration
46
Menu 3.2.2 Nozzle method
During practical flow calibration, the individual nozzle output on the
display is compared to the actual individual nozzle output. The output
displayed is corrected to read the actual output.
μ
ATTENTION! See menu [3.3 Boom] if no boom data has yet been
entered.
If a section has not been opened or a end nozzle is not closed, the
warnings below (next two pictures) will show up in the lowest line on
display. If the boom symbol on the 1
st
line flashes, set menu [2.2.1 AUTO
ON/OFF] to [0.0 km/h].
Method
1.
Open all boom sections. Switch the main ON/OFF to ON. Close
end nozzles (if fitted).
2.
Go to menu [3.2.2 Nozzle method]. The display will then show the
individual nozzle output per minute.
3.
Using a HARDI calibration jug, check the actual nozzle output per
minute. It is recommended that an average of several nozzles is
taken.
4.
Press .
5.
Correct the output shown on the display with the navigation keys
to read the average output measured with the calibration jug.
6.
Press
to
confirm.
NOZZLE METHOD
XX.XX L/min
3.2.2
NOZZLE METHOD
Open all
3.2.2
NOZZLE METHOD
Close end nozzle
3.2.2
NOZZLE METHOD
XX.XX L/min
3.2.2
Содержание HC 5500 SPRAY BOX III
Страница 6: ...Table of Contents 6 ...
Страница 8: ...1 EC Declaration 8 ...
Страница 10: ...2 Safety notes 10 ...
Страница 22: ...3 Description 22 ...
Страница 28: ...4 System setup 28 ...
Страница 56: ...7 Menu 3 Calibration 56 ...
Страница 64: ...8 Menu 4 Toolbox 64 ...
Страница 68: ...10 Maintenance 68 ...
Страница 74: ...11 Fault finding 74 ...
Страница 80: ...13 Technical specifications 80 ...
Страница 82: ...Index 82 ...
Страница 84: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...