43
7 - Menu 3, Calibration
Menu 3.1 Speed calibration
Menu 3.1.1 Sprayer
The calibration process is the same for each sensor type. In the following
example, a “speed sensor on sprayer” is used.
Shortcut button
when on the working screen.
1.
Press
a few seconds, until menu [3.1.1 Sprayer] is shown.
It is possible to connect the speed sensor at different locations. See
chapter 4 - System setup, for more about this. They are calibrated
in the following menus:
[3.1.1 Sprayer] Speed sensor on sprayer
[3.1.2 Tractor] Speed sensor on tractor
[3.1.3 Radar] Radar speed sensor
2.
Select with the navigation keys.
3.
Press
to confirm. The last confirmed sensor is the active speed sensor.
Shortcut button
when on the working screen.
4.
Press
until menu [3.1.X “Speed ....”] is shown.
5.
Choose speed sensor (Sprayer, Tractor or Radar)
6.
Press
to
confirm.
7.
Press
to read PPU value. PPU = pulses per unit.
μ
ATTENTION! Be aware that even if tractor speed sensor and radar speed sensor uses the same connector, the PPU
value may be very different.
μ
ATTENTION! The speed sensor can be calibrated theoretically or practically. The practical method is recommended.
SPEED
Sprayer
3.1.1
Содержание HC 5500 SPRAY BOX III
Страница 6: ...Table of Contents 6 ...
Страница 8: ...1 EC Declaration 8 ...
Страница 10: ...2 Safety notes 10 ...
Страница 22: ...3 Description 22 ...
Страница 28: ...4 System setup 28 ...
Страница 56: ...7 Menu 3 Calibration 56 ...
Страница 64: ...8 Menu 4 Toolbox 64 ...
Страница 68: ...10 Maintenance 68 ...
Страница 74: ...11 Fault finding 74 ...
Страница 80: ...13 Technical specifications 80 ...
Страница 82: ...Index 82 ...
Страница 84: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...