30
Technical specifications
Supply voltage
12 Volt DC
Minimum supply
11 Volt DC
Maximum supply
16 Volt DC
Maximum peak
20 Volt DC
Ambient temperature
– 10° C to + 55° C
Memory
Flash PROM non-volatile
Digital transducers
Square signal
Update frequency
4 times per second
Trigger high
5.0 to 12.0 Volt DC
Trigger low
0.0 to 0.5 Volt DC
Analog transducers
Supply
Loop
Input
4 to 20 mA
Minimum speed for volume regulation
2.0 km/h
Flow ranges for the flow transducers
Housing
Housing
Flow range
Orifice
PPU
identification
l/min
mm
value
S/67
One outside groove
5 - 150
13.5
120.00
S/67
No groove
10 - 300
20.0
60.00
S/67
Two outside grooves
35 - 600
36.0
125.00
Pressure drop over 13.5 mm orifice is 1
bar at 150 l/min.
Packaging information
Materials used for packaging are environmentally compatible.
They can be safely deposited or they can be burnt in an incinerator.
Recycling
Cardboard:
Can recycle up to 99% and therefore should be put into the
waste collection system.
Polyethylene:
Can be recycled.
When the HM 1500 / HC 2500 has completed its working life, it must be thor-
oughly cleaned. The synthetic fittings can be incinerated.
The printed circuit boards and metallic parts can be scrapped.