6
T1
65-0002
HC 2500 Controller with electric control unit
(EVC, CB)
Active boom width is calculated automatically when the boom sections are
operated.
NOTE:
Extended menu setting:
[
ON/OFF valve
] is [
Not present
] for EVC and CB.
[
Pressure system
] is [
No equalisation
]
See “Extended menu”.
1.
HC 2500 display
2.
Display connector cable
3.
To 12 Volt power supply
4.
Area switch (option)
5.
Speed transducer
6.
Flow transducer
7.
Box connector socket
8.
Spray box for electric con-
trol unit
9.
39 pin plug to control unit
10. Electric control unit
Power supply
The power supply is 12 Volt DC.
Brown wire is positive
“
t
”.
Blue wire is negative
“
-
”.
Power supply must come directly from the battery. The wires must have a
cross-sectional area of at least 1.0 mm
2
to ensure sufficient power supply.
NOTE:
Do not connect to the starter motor or generator/alternator. Warranty
is void if this is done.
Use the HARDI Electric distribution box (Ref. no. 817925) if the tractor has a
doubtful wiring.
Содержание HC 2500 Series
Страница 1: ...CONTROLLER HC2500 HM1500 Instructionbook 679050 SW 1 52 GB 07 2003 www hardi international com ...
Страница 36: ...34 26000700 Spare parts ...
Страница 37: ...35 ...
Страница 38: ...36 Notes ...