31
Chart for recording values
Menu
Function
1 - Values
2 - Values
3 - Values
Nozzle /Colour
[ Flow constant ]
Flow PPU
[ Speed constant ]
Speed UPP
Extended menu
Access the extended menu by pressing both arrow keys at the same time until
the menu changes.
The extended menu written in English only.
NOTE:
Re-start the system after leaving the Extended menu.
Menu
Function [ choices ]
[
Language
]
To select language.
[ GB, DK, F, E, D, Cz, SF, NL, I, S ]
[
Unit
]
To set unit of measurement. [ Metric, USA ]
[
ON/OFF valve
]
To select EC or EVC/CB control unit.
[ Present, not present ]
[
Pressure system
]
To select pressure system.
[ Equalisation, No equalisation ]
[
Control box
]
To indicate control box connection.
[ Lunch box, Spray box, Not connected ]
(To July 2003): Lunch box indicates rectangular control box.
(From Aug. 2003): Spray box indicates wave shaped control box.
[
Tank volume max
]
To pre-set tank volume indicated at start-up.
[
Analog adjust
]
To calibrate the optional transducer.
[ max., min., offset in mA ]
[
Analog unit text
]
To choose the unit of measurement.
[ Bar, PSI, deg C, deg F, % R.H ]
[
Regulation con.
]
For the sensitivity of the pressure regulation valve.
[
Min. press. cycle
]
Sets the minimum power supply for pressure
regulation. The value is increased until the pres-
sure regulation valve starts to turn.
Use page key to toggle between no regulation (
-
),
increase pressure (
) and