12
M A N .
A r e a x x x x . x x h a
Y x x x x x L
Automatic dosage
To alter the chosen application rate, press either arrow keys on the display. The
chosen quantity applied per area unit is shown. If the key is pressed again it
will raise or lower the chosen rate. When the key is released the display shows
the new rate for a moment and then returns to the main picture.
NOTE:
A minimum speed of 2.0 km/h is needed before the system will regu-
late automatically.
Manual dosage
To dose in manual mode, use the pressure switch on the control box. With HC
2500, the manual mode is indicated on the bottom line with a flashed text [
MAN.
] over the displayed information. Bottom line is cleared when [
MAN.
] is
displayed.
To go from manual to automatic dosage, briefly touch the arrow key
on the HC 2500.
Reading and reset of area trip
Area trip from 1 to 8 (
Y
) can be used for individual areas.
Area trip 0 is a tally of area trips 1 to 8. The treated area is memorised when the
system is switched off.
1. Press enter key for area covered and volume sprayed.
2. Press enter key again to return. If is not pressed again it will return
to the main picture after 15 seconds.
To reset the active register press the enter key continuously and a
5 second countdown will commence.
Reset of a register can be stopped if the enter key is released.
Alarms
Alarm warnings [
Vol. rate alarm
] or [
Tank alarm
] are flashed for 3 seconds
at a time on the top line over the displayed information.
Содержание HC 2500 Series
Страница 1: ...CONTROLLER HC2500 HM1500 Instructionbook 679050 SW 1 52 GB 07 2003 www hardi international com ...
Страница 36: ...34 26000700 Spare parts ...
Страница 37: ...35 ...
Страница 38: ...36 Notes ...