when
measuring 1000M
Ω
resistance the display reading will be 1010
and the correct measuring result should be 1010
10 = 1000 M
Ω
.
AUDIBLE CONTINUITY TEST
1.
2.
3.
Connect red test lead to “
Ω
” jack, black test lead to “COM” jack.
Set range switch to “
” position.
Connect test leads to two points of circuit to be tested. If continuity exists,
built-in buzzer will sound.
SPECIFICATIONS
Accuracy is specified for a period of one year after calibration and at 18
to 28
(64
°
F to 82
°
F) with relative humidity to 80%.
GENERAL
Maximum voltage between
terminals and earth ground
: CAT
II
1000V dc or 750V ac rms. (sine)
Display
:LCD, 1999 counts, updates 2-3/ sec.
Polarity indication
:“-”displayed for negative polarity
Overrange Indication
:Only figure “OL” on the display
Jaw opening capability
: 55mm (Max conductor size)
Power
:9V battery, NEDA 1604 or IEC 6F22
Low battery indication
:“
” appears on the display
Operating Environment
:0 to 40
Storage temperature
:-10
to 50
Temperature coefficient
:0.1
specified accuracy) /
( <18
or >28
)
Altitude
: 2000m
Size
: 282mm
104mm
47mm
Weight
: Approx.500g.
DC VOLTAGE
Range
Resolution
Accuracy
1000V
1V
±
1.0% of rdg
±
2 digits
Input Impedance: 10M
Ω
-7-