DANGER:
Failure to disconnect power supply prior
to installation may result in serious injury or death.
INITIAL INSTRUCTIONS
1. Turn off circuit breakers and wall switch to the fan
supply line leads.
1
OFF
OFF
ON
2a. Choose the desired mounting method:
2b. Make sure the installation site you choose allows a
minimum clearance of 7 ft. from the blades to the
floor and at least 30 in. from the ends of the blades
to any obstruction.
A. Standard Mounting:
Standard mounting is best
suited for ceilings 8 ft. or higher. For taller ceilings you
may want to use a longer downrod (not included).
B. Angle Mounting:
Angle-style mounting is best
suited for angled or vaulted ceilings. A longer downrod
is sometimes necessary to ensure proper blade
clearance. If using the angle mount, make sure the
ceiling angle is not steeper than 20°.
C. Flush Mounting:
Flushmount installation is used
for ceiling less than 8 ft. high.
2a
A
B
C
2b
7 ft. MIN.
30 in.
MIN.