manualshive.com logo in svg
background image

1. Connect the GREEN wires from the hanger ball of 

downrod assembly (D) and mounting bracket (A) to 

the supply ground (GREEN or bare) wire. Securely 

connect wires using wire connector (AA).

2. Securely connect the fan WHITE wire to the supply 

WHITE wire using wire connector (AA). Securely 

connect the fan BLACK and BLUE wires to the supply 

BLACK wire using wire connector (AA).

Note: 

Flushmount installation will not use the Green 

wire from the downrod assembly (D).

Hardware Used

Wire Connector

x 1

AA

Hardware Used

Wire Connector

x 2

AA

1

Supply 
Ground Wire

Green Wire from

Mounting Bracket

Green Wire from

Hanger Ball

A

D

2

Black 

Fan Wire

Blue 

Fan Wire

BLACK

GREEN

WHITE

White

Fan Wire

      

WARNING: 

To avoid possible electrical shock, be sure electricity is turned off at the main fuse 

      box before hanging. 
      

WARNING: 

If you are not sure if the outlet box is grounded, contact a licensed electrician for 

      advice, as it must be grounded for safe operation. 
      

WARNING: 

If house wires are of different colors than referred to in the following steps, stop 

      immediately. A professional electrician is recommended to determine proper wiring.
      

WARNING: 

If you feel that you do not have enough electrical wiring knowledge or experience, 

      have the fan installed by a licensed electrician.

10

Lowes.com/harborbreeze

WIRING INSTRUCTIONS

Note:

 This is only one way to wire the fan; consult a 

qualified electrician if it is not applicable to your home.

Note:

 The BLACK wire is hot power for the fan. The 

WHITE wire is common for the fan and light. The BLUE 

wire is hot power for the light. The GREEN wire is the 

ground wire.

Содержание CPJ1240

Страница 1: ...ions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday EB14464 ATTACH YOUR RECEIPT...

Страница 2: ...nitial Instructions Standard Angle Mounting Instructions Flushmount Instructions Wiring Instructions Final Instructions Operating Instructions Care and Maintenance Troubleshooting Limited Lifetime War...

Страница 3: ...1 I Blade Iron 5 J Blade 5 K Light Kit 1 L Glass Bowl 3 M Bulb 3 N Clevis Pin preassembled to Coupling F 1 O Hairpin Clip preassembled to Coupling F 1 P Coupling Screw preassembled to Coupling F 2 Q...

Страница 4: ...FRQQHFWLRQV LI WKH FRQGXFWRU RI D IDQ LV LGHQWLILHG DV D JURXQGHG FRQGXFWRU WKHQ LW VKRXOG EH FRQQHFWHG WR D JURXQGHG FRQGXFWRU SRZHU VXSSO I WKH FRQGXFWRU RI D IDQ LV LGHQWLILHG DV DQ XQJURXQGHG FRQG...

Страница 5: ...a tag to the service panel Do not use bulbs having a wattage greater than the maximum value stated on the fixture and in this manual Using a higher wattage bulb than specified will increase fixture te...

Страница 6: ...the floor and at least 30 in from the ends of the blades to any obstruction A Standard Mounting Standard mounting is best suited for ceilings 8 ft or higher For taller ceilings you may want to use a l...

Страница 7: ...remove them 1 Place downrod assembly D through canopy B canopy cover C and coupling cover E Note If using the angle mount make sure open end of mounting bracket A is installed facing the higher point...

Страница 8: ...eaving approximately 6 to 9 inches above the top of the downrod assembly D Strip 1 2 inch of insulation from the end of each fixture wire 4 Carefully lift assembly and rest the hanger ball of downrod...

Страница 9: ...hen attach canopy B to motor housing G with previously removed screws Tighten securely 3 Raise assembly and temporarily place one side of canopy B onto hook of mounting bracket A This will leave hands...

Страница 10: ...avoid possible electrical shock be sure electricity is turned off at the main fuse box before hanging WARNING If you are not sure if the outlet box is grounded contact a licensed electrician for advic...

Страница 11: ...emove the other two mounting bracket screws R 2 Position one blade iron I under blade J Insert three blade screws BB through blade J and into blade iron I Tighten each blade screw BB evenly starting w...

Страница 12: ...borbreeze H K S G 4 S H 3 Loosen do not remove the motor screws T from motor housing G and discard the preassembled motor blocks Slide the blade assemblies onto motor housing G and tighten the motor s...

Страница 13: ...0 watts the fixture will automatically turn off When replacing bulbs ensure bulb wattage is below 190 watts Lowes com harborbreeze 7 Slide glass bowl L to each socket securing with socket rings U FINA...

Страница 14: ...switch RIGHT and see a SNOWFLAKE icon 9 Connect the fobs DD to the appropriate pull chains 1 The fob DD marked with a fan image is for motor speed control High Medium Low and Off Pull once for each p...

Страница 15: ...od 4 Wire connectors inside switch housing rattling 4 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing 5 Crac...

Страница 16: ...4 Pull chain switch not on 4 Pull switch chain 1 Wrong wire connection 1 Refer to Step 1 page 10 to ensure all wire connections were done correctly 2 Bulb is burned out 2 Replace the bulbs Light does...

Страница 17: ...finish rusting pitting tarnishing corroding or peeling Brass finish fans maintain their beauty when protected from varying weather conditions The duration of any implied warranty which can not be dis...

Страница 18: ...LLC All Rights Reserved E D C B A I J L V U K CC DD A Mounting Bracket A102 0132031 B Canopy A101 0347084 C Canopy Cover A108 0230084 D Downrod Assembly A103 0156084 E Coupling Cover A106 1262084 I Bl...

Отзывы: