Hanter HM 2088 Скачать руководство пользователя страница 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hanter® Wireless Intelligent Alarm Systems - Model HM2088

                 

 

4.2  Optional Accessories   

   

 

 

 

 

4.2.1  Wireless Smoke Detector 

The Wireless Smoke Detector is widely used in professional security & 
protection alarm system. It will send RF signal to the Control Panel when it 
detects smoke. It is recommended to locate this unit at a less or non-smoke 
area.  

4.2.2  Wireless Gas Leak Detector 

The Wireless Gas Leak Detector is widely used in professional security & 
protection alarm system. It will send RF signal to the Control Panel when it 
detects natural gas, piping coal gas and liquefied petroleum gas etc. 

4.2.3  Wireless Glass Break Detector   

The Glass Break Detector delivers effective coverage in the presence of plate, 
tampered, and laminated glass, with easy sensitivity adjustment. The optimal 
performance is dependent on the secured and vibration-free mountings. The 
Glass Break Detector can be used in most protected areas, including glass 
display panel and rooms with blinds, curtains, or multiple windows, as long as 
careful coverage tests are conducted. 

4.24

 

  Wireless Door Chime 

The Wireless Door Chime is ideal to be installed outside the entrance area. 
The visitor can notify the premise owner by pressing the button. 

Part 5 – System Settings and Operations 

5.1   System Settings

 (all functions setting under disarming status) 

5.1.1 Programming Telephone Numbers 

(maximum 4 sets of numbers) 

Press the “

  ” key of the Keychain Remote Control to enter disarming status, 

then press “*” key on the Control Panel, input the designated telephone 
numbers follow by input *1#, repeat same process for the 2

nd

 set preset number 

and end with *2#. The rest are the same except for signing off with *3# and 
*4# respectively after each entry. *1# is memory No 1, *2# is memory No 2 
and so on. 

         

Note: With the completing program the 4 set of numbers will maximize the duration 

of Alarm Buzzing to approximately 5 minutes

a. 

To Program Telephone Number 

 

  Example: To set 12345678 as 1

st

 set of Telephone Number. 

 

 Step 1:  Press the “   ” key of the Keychain Remote Control 

 

  Step 2:    Press “*” key on the Control Panel 

 

  Step 3:    Press 12345678*1# on the Control Panel 

Step 4: The control Panel will emit “Ding Dong” sound to confirm 

successfully programmed. 

Step 5:    Repeat the same steps for the balances 2

nd

, 3

rd

 & 4

th

 set of Telephone 

numbers. 

‹

 P.  7

 

Hanter® Wireless Intelligent Alarm Systems - Model HM2088

   

                   

 

Part6 -

 

System Installation and Testing 

 

6.1  Control Panel 

 

 

 
 
The Control Panel can be placed or installed on a desk or the wall (preferably a 
hidden spot but easily accessible) 

 

Step 1: Connect the AC adapter.

 

Insert the adapter jack

 

to the “9V 300mA” port of 

the Control Panel. Then plug the AC adapter into an electrical source.   

Step 2: Connect an incoming Telephone line to “Line in” port, Grey line to desktop 

telephone set and white line to incoming line connector. 

 

  Step 3: Insert the Siren jack into the “Siren” port. 

 
Reminder: 
In order to make the alarm system operates properly, all the above cables must 

be well connected

.  

 

Zone Connector: 

The Zone Connector is the connection port to connect wired detectors. It comes with 
two group of wire: 
Group 1 :    Yellow wire & blue wire 
Group 2 :    white wire & red wire 
 
It can be connect to 2 sets of detectors and using short circuit to trigger alarm. The 
blue and red wire link to ground whereby the Yellow wire and white wire are 
connected to Detectors. 

 

‹

 P.  14 

Содержание HM 2088

Страница 1: ...rs and detectors must be placed or installed under stable condition 9 3 The Control Panel switches sensors and detectors are not advisable to be placed or installed at the area with heavy magnetic int...

Страница 2: ...of the detector is different from Control Panel Make sure both detector and Control Panel is same frequency The coding chips of detector is not compatible with Control Panel Make sure the coding chips...

Страница 3: ...the preset telephone numbers to call for help The alarm system will guard your home when you are away or resting P 3 Hanter Wireless Intelligent Alarm Systems Model HM2088 Item Issues Possible Cause...

Страница 4: ...quency 315MHz 0 2MHz Operating Temperature 10 C 55 C Dimension 144x143x43mm Relative humidity 95 Part 8 Trouble Shooting Item Issues Possible Cause Solution 1 Telephone line is in working condition bu...

Страница 5: ...r than 0 3 to 1 2 meters and inside the range of gas source with direct 1 5meters b The detector should not be located near any areas that emit gas cooking area c The detector should not be located cl...

Страница 6: ...odel HM2088 6 2 Wireless Door Window Magnet Switch The Door Window Magnet Switch is equipped with a magnet bar Movement of the magnet triggers an internal sensor in the switch We recommend locating th...

Страница 7: ...me process for the 2nd set preset number and end with 2 The rest are the same except for signing off with 3 and 4 respectively after each entry 1 is memory No 1 2 is memory No 2 and so on Note With th...