Hanter® Wireless Intelligent Alarm Systems - Model HM2088
Part 3 – Function and Feature Introduction
3.1
Function Introduction
1. Arming & disarming by Keychain Remote Control and Keypad
2. Long distance remote control by any telephone
3. Remote control of the Home Electrical Appliances by telephone
4. Live feeding record & listening by telephone
5. Alarm reporting on illegal entries by PIR detector and Magnetic Door
Switches
6. Alarm Siren buzzing to warn for illegal intrusion or possible intrusion
7.
Smoke & fire alarm
8.
Toxic gas leaking alarm
9. Emergency Help alarm
10. Auto-dialing to preset phone numbers for alarm notification
11.
Two way voice communications between telephone & Control Panel
P. 4
Hanter® Wireless Intelligent Alarm Systems - Model HM2088
Part 7--Technical Specifications
Control Panel
•
Operating voltage: DC9V
●
Receive frequency: 315MHz±0.2MHz
•
Operating Temperature:-10°C ~ +55°C
●
Dimension:144x143x43mm
•
Relative humidity:<95%
Part 8 --Trouble Shooting
Item Issues
Possible
Cause
Solution
1
Telephone line is in
working condition, but
unable to make call to
preset telephone
numbers when alarm is
triggered.
Telephone line to
Control Panel may not
be connected properly
Ensure the telephone line to
Control Panel is well
connected.
Pre-set auto-dial
numbers is not properly
programmed.
Program the preset auto-dial
numbers in accordance to the
user manual.
2 Control
Panel
trigger
siren immediately while
enter arming status, but
no auto-dial was make.
Telephone line to
Control Panel may not
be connected properly.
(Activated the anti-cut
function)
Ensure the telephone line to
Control Panel is well
connected
3
Control Panel is in
working condition, but
the detector has no
response
The batteries energy of
detector is low.
Change batteries
Interference of external
signals.
Test the Control Panel and
detector in close range
The battery is not well
connected
Reinstall the battery or clean
the battery contact point
4
No response from
Control Panel when
power is on
The power supply is not
well connected or not in
working condition,
Reconnect the power supply
and make sure it plug-in to
right port or change the new
adapter.
P. 17
Door
Chime
Siren
Emergency
Button
Emergency
Button