Part 2 – System Workflow   

 

 

 

 

                                                   

Long Distance Remote Controlling 

                                           

 

 

                                     

Transmission    Notification

 

 

 

                                             

 

Emergency  Arm  Door    Alarm 

Help            / Disarm    Bell 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                       

Control Panel 

HM2088 

CMS

 

Mobile phone

 

Telephone

 

Motion Sensor    

Smoke Detector

 

Gas Leak 

Detector

         

Glass Break 

Detector

 

Door Switch 

Remote   

Control

Microwave oven 

Illuminator

 

Fan

 

Electric curtain 

Hanter® Wireless Intelligent Alarm Systems - Model HM2088

               

 

Part 3 – Function and Feature Introduction 

3.1

 

Function Introduction 

1.    Arming & disarming by Keychain Remote Control and Keypad 
2.    Long distance remote control by any telephone 
3.    Remote control of the Home Electrical Appliances by telephone 
4.    Live feeding record & listening by telephone 
5.    Alarm reporting on illegal entries by PIR detector and Magnetic Door     

Switches 

6.    Alarm Siren buzzing to warn for illegal intrusion or possible intrusion 
7.

 

Smoke & fire alarm 

8.

 

Toxic gas leaking alarm 

9.  Emergency Help alarm  
10.    Auto-dialing to preset phone numbers for alarm notification 
11.

 

Two way voice communications between telephone & Control Panel 

                                         

‹

 P.  4 

Hanter® Wireless Intelligent Alarm Systems - Model HM2088

                               

 

Part 7--Technical Specifications 

Control Panel   

 

Operating voltage: DC9V                         

● 

Receive frequency: 315MHz±0.2MHz 

 

Operating Temperature:-10°C ~ +55°C   

●  

Dimension:144x143x43mm   

 

Relative humidity:<95% 

Part 8 --Trouble Shooting 

Item Issues 

Possible 

Cause 

Solution 

 

Telephone line is in 

working condition, but 

unable to make call to 

preset telephone 

numbers when alarm is 

triggered. 

Telephone line to 

Control Panel may not 

be connected properly

 

Ensure the telephone line to 

Control Panel is well 

connected.

 

Pre-set auto-dial 

numbers is not properly 

programmed. 

Program the preset auto-dial   

numbers in accordance to the 

user manual.

 

2 Control 

Panel 

trigger 

siren immediately while 

enter arming status, but 

no auto-dial was make.

 

Telephone line to 

Control Panel may not 

be connected properly. 

(Activated the anti-cut 

function) 

Ensure the telephone line to 

Control Panel is well 

connected 

 

 

Control Panel is in 

working condition, but 

the detector has no 

response 

 

 

The batteries energy of 

detector is low.

 

Change batteries 

 

Interference of external 

signals. 

Test the Control Panel and 

detector in close range

 

The battery is not well 

connected 

 

Reinstall the battery or clean 

the battery contact point

 

No response from 

Control Panel when 

power is on 

 

The power supply is not 

well connected or not in 

working condition, 

Reconnect the power supply 

and make sure it plug-in to 

right port or change the new 

adapter. 

   

‹

    P.    17 

Door 

Chime

Siren

 

Emergency 

Button

 

Emergency 

Button

 

Содержание HM 2088

Страница 1: ...rs and detectors must be placed or installed under stable condition 9 3 The Control Panel switches sensors and detectors are not advisable to be placed or installed at the area with heavy magnetic int...

Страница 2: ...of the detector is different from Control Panel Make sure both detector and Control Panel is same frequency The coding chips of detector is not compatible with Control Panel Make sure the coding chips...

Страница 3: ...the preset telephone numbers to call for help The alarm system will guard your home when you are away or resting P 3 Hanter Wireless Intelligent Alarm Systems Model HM2088 Item Issues Possible Cause...

Страница 4: ...quency 315MHz 0 2MHz Operating Temperature 10 C 55 C Dimension 144x143x43mm Relative humidity 95 Part 8 Trouble Shooting Item Issues Possible Cause Solution 1 Telephone line is in working condition bu...

Страница 5: ...r than 0 3 to 1 2 meters and inside the range of gas source with direct 1 5meters b The detector should not be located near any areas that emit gas cooking area c The detector should not be located cl...

Страница 6: ...odel HM2088 6 2 Wireless Door Window Magnet Switch The Door Window Magnet Switch is equipped with a magnet bar Movement of the magnet triggers an internal sensor in the switch We recommend locating th...

Страница 7: ...me process for the 2nd set preset number and end with 2 The rest are the same except for signing off with 3 and 4 respectively after each entry 1 is memory No 1 2 is memory No 2 and so on Note With th...

Страница 8: ...try of telephone number press to exit and reset 5 1 2 Password setting The default password is 1234 you may change this password according to the following steps Step 1 Press key of the Keychain Remot...

Страница 9: ...s to allow the user to have enough time to leave the monitored or detected compound The Away Arm LED will light after 30 seconds a Operate by Keychain Remote Control Press of the Keychain Remote Contr...

Страница 10: ...Hanter Wireless Intelligent Alarm Systems Model HM2088 5 2 6 Anti cut During armed status when the telephone line is cuts the Control Panel will auto matically trigger the siren Note This feature will...

Отзывы: