Hanter® Wireless Intelligent Alarm Systems - Model HM2088
Part 1 - System Overview
The HM2088, Home/Commercial Digital Wireless Intelligent Security Alarm
System, has a Micro-Processor Chip and wireless RF Control Technology to ensure
the reliabilities, easy installation and operation of the system.
The system consists of a Control Panel that can be installed inside any hidden area
of an office or home. The monitoring sensors such as Wireless Infrared Detector,
Wireless Magnetic Door/Window Switch, Wireless Smoke Detector, Wireless Gas
Leak Detector etc. can mount onto a spot that requires monitoring. The arming and
disarming of the system can operate through the Keychain Remote Control or
keypad of the Control Panel. When the system is armed, any of the
sensors/switches/detectors detects a signal will wirelessly transmit signal to the
Control Panel. It will then trigger the siren and immediately autodial the preset
phone numbers to transmits the pre-recorded alarm voice message to the phone
owner or monitoring centers. When the alarm signal received, the owner or the
monitoring center can take the appropriate action or even report to the police
accordingly. All process will only take a few tens of seconds. The Alarm System
also includes functions of Wireless Door Chime and Long Distance Remote
Controlling of Home Electrical Appliances via telephone or mobile phone.
The other additional feature is to protect in case of emergency at home for the aged
persons or children. The Emergency Help Button can be triggered in order to
auto-dial the preset telephone numbers to call for help. The alarm system will guard
your home when you are away or resting.
P. 3
Hanter® Wireless Intelligent Alarm Systems - Model HM2088
Item Issues
Possible
Cause
Solution
5
During the disarming
status, siren triggered
and auto-dial the
preset telephone
numbers
One of the detectors might be
coded with Emergency Mode
coding
Reset the coding of the
detector according to the
type of detector
Control Panel saved signal the
can cause interference
Delete the saved signal of
the Control Panel and reset
the coding of detectors
6
Alarm is triggered
but the alarm led
light is not on
Telephone line to Control Panel
may not be connected properly
Ensure the telephone line to
Control Panel is well
connected
The preset auto-dial number is
not programmed
Program the preset auto-dial
numbers
7 Control
Panel
can
auto-dial to preset
mobile phone
numbers, but the
success calls rate is
inconsistently
The telephone line connected to
Control Panel is over loaded
with too much extension lines
Change to a non extension
telephone line.
The reception signal of the
mobile phone set is not stable.
The battery is fitted correctly or
not
Change it to fixed telephone
line or new mobile phone
set. Re-insert or clear the
battery
8
Alarming LED light
always on
Control Panel not disarmed
properly
Disarm again.
9 Control
Panel
can
auto-dial preset
telephone number
but cannot activate
the siren
Activated the Silent Alarm
feature. (For Model 2088 series
onward)
Deactivate the Silent Alarm
feature.
The siren jack not plug-in
properly
Plug the siren jack properly.
10
No voice message
was heard
when
receive telephone
call.
The telephone line connected to
Control Panel is over loaded
Use a non-extension
telephone line
P. 18