8 - 20
Hanskamp AgroTech B.V. (The Netherlands)
www.hanskamp.nl/en
MultiFill
EN
Dosing system - Dosiersystem - Système de dosage - Doseersysteem
Installing the float in the MultiDos storage tank:
1.
Install the float on the float valve (fig. 2).
2.
Drill a 22 mm hole, 440 mm from the bottom of the container (fig. 3 and 4).
3.
Twist the first of the two plastic nuts off the float (fig. 5).
4.
Insert the float valve set through the hole, fix the float with plastic nuts (fig. 7).
5.
Screw the adaptor nipple (art. no. 001-170-001) tightly onto the float valve by
hand (fig. 5).
Installing/connecting multiple drums:
1.
Connect the drums with the aid of the T-coupling (art. no. 001-178-000) (fig. 8).
2.
Secure the tube with cable ties, preferably place the tube in a protective sleeve.
Caution! Make sure that the tube is not pinched when fixing it.
Caution! Drill a small hole into the top of the storage drum for ventilation
purposes.
5
6
2
3
4
7
8
Caution! Fill the container completely
by hand the first time. Let the MultiFill
refill only the last millilitres.
6
Orifice supplied as standard (small).
Use with low viscosity fluids only.
Install large orifice (supply small orifice
separately).