Maintenance:
Check the MultiFill system every day for failures and wear. Carry out a visual inspection
of the suction and pressure hose and the electrical wiring. Replace the Hanskamp-
QualityTube if it shows signs of wear (leakage), according to the steps described (see
instructions from step 6). A suitable repair kit can be obtained from Hanskamp. Also
check the rollers and bearings for wear. For these too, Hanskamp can supply repair kits.
Caution! Always disconnect the pump motor from the power supply before
carrying out maintenance and/or disassembly.
Disassembly:
In case of disassembly, all parts must be separated according to material type and must
be processed within the proper type of waste management system.
Overview of changes included in this installation and operation instructions:
Warranty limitations:
The warranty excludes costs and expenses due to:
-
Use of the units for purposes other than intended, non-compliance with the
specifications in the installation and operation instructions;
-
The consequences of any intervention by engineers other than engineers
recognised and approved by Hanskamp for carrying out service, maintenance and
other technical work;
-
Incidents such as freezing, ice, fire, flooding, inundation or any other form of
extreme water damage and lightning;
-
Defects in the electrical system or grounding system;
-
Damage to the electrical system due to vermin and the like.
The warranty is not applicable to consequential damage that is not related to the
machine itself. All systems have been tested. However, in the event of disturbance,
Hanskamp cannot be held responsible for consequential damage.
Nr.
Release date
Chapter(s)
Notes
1
08/2014
First edition
1.1
03/2015
All
New address
1.2
04/2015
All
Update of illustrations
1.3
10/2015
All
General review
1.4
06/2016
Article numbers changed
1.5
10/2017
All
Added articles 001-006-002, 003-529-005 and 003-524-001 in parts list
1.6
01/2018
All
Multiple couplings replaced by 1 coupling
1.7
04/2018
All
Auto-stop MultiFill
1.8
07/2018
Components
Wall plug power supply changed from 12V DC to 24V DC
1.9
01/2019
Technical specifications
Pressure switch changed
2.0
03/2019
Installation float valve
Added warning notice to fill up the container completely at first use
2.1
08/2019
All
Knurled screw added & upgrade to new MF-motor
2.2
02/2020
Page 12
Changed warning after step 24.
2.3
05/2020
Page 10
Added PCB overview
2.4
09/2021
Page 10 + 15
Switch-off pressure increased from 1.3 to 1.5 bar
2.5
10/2021
Page 8 + 11 + 15 + 16 + 17
Transport hose changed to 14x10 mm
2.6
02/2022
Page 10 + 15
Adjusted cut-out pressure (1.5 to 2 bar) and start-up pressure (0.3 to 0.8 bar)