15
SafetyandImportantInformation
Hansgrohe products are safe provided they are installed,
used and maintained in accordance with these instructions
and recornrnendations.
Please read these instructions thoroughly and retain for
future use.
The plumbing installation of this thermostat mixing valvemust
comply with the requirements of UK
Water Regulations/Bylaws (Scotland), Building Regulati-
ons or any other regulations specified by the local Water
Authority and supplier.
The installation of thermostatic mixing valves must comply
with the requirements of the Water Supply (Water Fittings)
Regulations 1999.
We strongly recommend that you use a plumber registered
with or a member of an Association:
Chartered Institute of Plumbing and Heating Engineering
(CIPHE)
Water Industry Approved Plumber Scheme (WIAPS)
Dispose of plastic bags carefully
Keep children well away from the work area.
Check for hidden pipes and cables in the wall before
drilling holes.
The unit must be mounted on a finished waterproofed wall
surface (usually tiles).
If you are using power tools (e.g. to drill holes) wear sa-
fety glasses and always disconnect tools from the power
supply after use.
Do not operate the shower unit if the hand shower or spray
hose has been damaged or is blocked.
Do not block the flow of water from the hand shower, by
placing it on your hand or any other part of your body or
foreign object.
The thermostatic unit should be serviced annually by a
qualified person to ensure maximum safety during use.
The thermostatic mixing valve will be installed in such a
position that maintenance of the TMV and its valves and the
commissioning and testing of the TMV can be undertaken.
The mixer is fitted with check valves (page 14 pos.
96644000). There are filters on the thermostatic element
too (page 14 pos. A and 96922000).
The fitting of isolation valves is required (preferred location
page 17 Installation Requirements)
Onthefollowingpages16-21youcan
findimportantinformationonlyforthe
installationinUK
TechnicalHotlineforUKonly
01372465655
E-mailforUKonly
(Diese Servicehotline ist nur für das Vereinigte König-
reich Großbritannien, nicht z. B. für Deutschland)
Содержание Ecomax 13356000
Страница 6: ...6 X X 36 mm X 36 1 3b 2 3a 1 2 1 2 Silicone max 39 mm max 5 mm 1 2 5 4 36 mm SW 24 mm...
Страница 7: ...7 6 7 8 SW 30 mm 17 Nm...
Страница 8: ...8 Ecomax 13354000 Ecomax 13356000 R 1 2 R 1 2 P IX DVGW SVGW ACS WRAS ETA KIWA 13354000 X 13356000 X...
Страница 9: ...9 SW 3 mm SW 3 mm 2 Nm 1 3 4 2 5 6...
Страница 10: ...10 z B 42 C for example 42 C 4 3 1 2 5 1 2 S W 3 m m S W 3 m m 2 N m...
Страница 11: ...11 5 6 SW 30 mm SW 30 mm 17 Nm SW 12 mm SW 12 mm 20 Nm 4 1 1 2 2 3 1 2 SW 24 mm 1 2 SW 24 mm 20 Nm 1 2...
Страница 12: ...12 1 2 3...
Страница 13: ...13 schlie en close 90 ffnen open 1 2 kalt cold 40 C warm hot 90 1 2...