16
TechnicalData
This thermostatic valve will suit supplies of:
13354000: High pressure (HP-S/ T41) / Low pressure
(LP-S)
13356000: High pressure (HP-S) / Low pressure (LP-S)
Operating pressure:
max. 10 bar
Recommended operating pressure:
0.2 - 5 bar
Test pressure:
16 bar
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Rate of flow from bath spout:
58 l/min. @ 3 bar
Rate of flow from shower outlet:
18 l/min. @ 3 bar
Maximum outlet temperature:
43°C +/-*
Safety check:
40°C
Hot water connection:
Left hand
Cold water connection:
Right hand
Minimum difference between hot
water and mixed water temperature:
6 K
Hot and cold supply pressure should be balanced
Mixedwatertemperature
Application
Mixed water temperature
(at point of discharge).
Shower
41°C max.
Washbasin
41°C max.
Bath (44°C fill)
44°C max.
Bath (46°C fill)
46°C max.
* For preset outlet temperature adjustment – See page 10.
NB.
If a water supply is fed by gravity then the supply
pressure should be verified to ensure the conditions of use
are appropriate for the valve. Valves operating outside of
these supply conditions cannot be guaranteed to operate
as a TMV2 or TMV3 valve.
Recommendedoutlettemperatures
The BuildCert TMV scheme recommends the following
set maximum mixed water outlet temperatures for use in
all premises:
44°C for bath fill but see notes below;
41°C for showers;
41°C for washbasins.
The mixed water temperatures must never exceed 46°C.
The maximum mixed water temperature can be 2°C above
the recommended maximum set outlet temperatures.
Note:
46°C is the maximum mixed water temperature from
the bath tap. The maximum temperature takes account of the
allowable temperature tolerances inherent in thermostatic
mixing valves and temperature losses in metal baths.
It is not a safe bathing temperature for adults or children.
The British Burns Association recommends 37 to 37.5°C as
InstallationRequirements
This thermostatic mixer valve must be installed in comp-
liance with current Water Regulations. If you have any
doubts about the Water Regulation requirements contact
your local water services provider or use the services of a
professional plumber.
The thermostatic mixing valve must be installed in a posi-
tion that is easily accessible for commissioning and future
servicing.
This mixer valve is suitable for use with the following water
supply systems:
Gas Combination Boiler (multi-point) 1.0 - 10 bar*
Unvented System (pressure balanced) 1.0 - 10 bar
Pumped System 1.0 - 10 bar
IMPORTANT:
If you install this mixer with a gravity fed
system, there must be a minimum head (vertical distance)
from the underside of tlie cold water storage tank to the
showerhead position of at least 5 metre.
Before connecting the mixer, water should be flushed
through the system to remove all debris that might otherwise
damage the valve.
* If pressure is in excess of 3.5 bar, a pressure-reducing
valve should be fitted.
a comfortable bathing temperature for children. In premises
covered by the Care Standards Act 2000, the maximum
mixed water outlet temperature is 43°C
SupplyConditionsTMV2
Operatingpressurerange
High
pressure
Low
pressure
Maximum static pressure - bar 10
10
Flow pressure, hot and cold - bar 1 to 5
0.2 to 1
Hot supply temperature - °C
52 to 65
52 to 65
Cold supply temperature - °C
5 to 20
5 to 20
SupplyConditionsTMV3
Operatingpressurerange
High
pressure
Low
pressure
Maximum static pressure - bar 10
10
Flow pressure, hot and cold - bar 0.5 to 5
0.1 to 1
Hot supply temperature - °C
55 to 65
55 to 65
Cold supply temperature - °C
5 to 25
5 to 25
Содержание Ecomax 13356000
Страница 6: ...6 X X 36 mm X 36 1 3b 2 3a 1 2 1 2 Silicone max 39 mm max 5 mm 1 2 5 4 36 mm SW 24 mm...
Страница 7: ...7 6 7 8 SW 30 mm 17 Nm...
Страница 8: ...8 Ecomax 13354000 Ecomax 13356000 R 1 2 R 1 2 P IX DVGW SVGW ACS WRAS ETA KIWA 13354000 X 13356000 X...
Страница 9: ...9 SW 3 mm SW 3 mm 2 Nm 1 3 4 2 5 6...
Страница 10: ...10 z B 42 C for example 42 C 4 3 1 2 5 1 2 S W 3 m m S W 3 m m 2 N m...
Страница 11: ...11 5 6 SW 30 mm SW 30 mm 17 Nm SW 12 mm SW 12 mm 20 Nm 4 1 1 2 2 3 1 2 SW 24 mm 1 2 SW 24 mm 20 Nm 1 2...
Страница 12: ...12 1 2 3...
Страница 13: ...13 schlie en close 90 ffnen open 1 2 kalt cold 40 C warm hot 90 1 2...