SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
The hot and cold supplies must be of equal pres-
sures.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Thermostaticmixerinconjunctionwith
combinationboilers
• If fitting a hand shower remove the water limiter from
the shower.
• If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Rate of flow Bath Spout:
58 l/min 0,3 MPa
Rate of flow Shower outlet:
18 l/min 0,3 MPa
• Safety against backflow
• The product is exclusively designed for drinking water!
English
Adjustment
(see page 9)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Do not use silicone containing acetic acid!
Symboldescription
Maintenance
(see page 11)
• The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
SafetyFunction
(see page 10)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
4
Содержание Ecomax 13356000
Страница 6: ...6 X X 36 mm X 36 1 3b 2 3a 1 2 1 2 Silicone max 39 mm max 5 mm 1 2 5 4 36 mm SW 24 mm...
Страница 7: ...7 6 7 8 SW 30 mm 17 Nm...
Страница 8: ...8 Ecomax 13354000 Ecomax 13356000 R 1 2 R 1 2 P IX DVGW SVGW ACS WRAS ETA KIWA 13354000 X 13356000 X...
Страница 9: ...9 SW 3 mm SW 3 mm 2 Nm 1 3 4 2 5 6...
Страница 10: ...10 z B 42 C for example 42 C 4 3 1 2 5 1 2 S W 3 m m S W 3 m m 2 N m...
Страница 11: ...11 5 6 SW 30 mm SW 30 mm 17 Nm SW 12 mm SW 12 mm 20 Nm 4 1 1 2 2 3 1 2 SW 24 mm 1 2 SW 24 mm 20 Nm 1 2...
Страница 12: ...12 1 2 3...
Страница 13: ...13 schlie en close 90 ffnen open 1 2 kalt cold 40 C warm hot 90 1 2...