2

PRELIMINARY EXAMINATION .............................................................................................. 3
GENERAL DESCRIPTION....................................................................................................... 4
ABBREVIATIONS................................................................................................................. 4

SPECIFICATIONS ................................................................................................................ 5
PRECISION AND ACCURACY ................................................................................................. 5
PRINCIPLE OF OPERATION .................................................................................................. 6
FUNCTIONAL DESCRIPTION ................................................................................................. 7
GUIDE TO DISPLAY CODES .................................................................................................. 9
GENERAL TIPS FOR AN ACCURATE MEASUREMENT .............................................................. 11
MEASUREMENT PROCEDURE ............................................................................................. 13
VALIDATION PROCEDURE .................................................................................................. 15
CALIBRATION PROCEDURE ................................................................................................ 16

BATTERY REPLACEMENT .................................................................................................... 18
ACCESSORIES .................................................................................................................. 18
CE DECLARATION OF CONFORMITY..................................................................................... 19
WARRANTY ...................................................................................................................... 19

Dear Customer,
Thank you for choosing a Hanna product. This manual will provide you with the necessary information
for the correct use of the instrument. Please read it carefully before using the meter. If you need

additional technical information, do not hesitate to e-mail us at [email protected].
This instrument is in compliance with   directives.

All rights are reserved. Reproduction in whole or in part is prohibited without the written consent
of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.

TABLE OF CONTENTS

19

Recommendations for Users

Before using these products, make sure that they are
entirely suitable for your specific application and for
the environment in which they are used.
Operation of these instruments may cause

unacceptable interferences to other electronic
equipments, this requiring the operator to take all
necessary steps to correct interferences.
Any variation introduced by the user to the supplied
equipment may degrade the instruments' EMC
performance.
To avoid damages or burns, do not put the instrument
in microwave oven. For yours and the instrument
safety do not use or store the instrument in hazardous
environments.

HI 95701 is warranted for two years against defects in workmanship and materials when used for its
intended purpose and maintained according to the instructions.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact your dealer. If under warranty, report the model number, date of
purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you
will be notified of the charges incurred.
If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization
Number from the Customer Service Department and then send it with shipment costs prepaid. When
shipping any instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date

of purchase.

HANNA instruments®

 reserves the right to modify the design, construction and appearance of its

products without advance notice.

CE DECLARATION OF CONFORMITY

WARRANTY

Содержание HI 95701C

Страница 1: ...1 Instruction Manual HI 95701C Free Chlorine ISM w w w h a n n a i n s t c o m This Instrument is in Compliance with the CE Directives 20 MAN95701R2 05 06 w w w h a n n a i n s t c o m...

Страница 2: ...take all necessary steps to correct interferences Any variation introduced by the user to the supplied equipment may degrade the instruments EMC performance To avoid damages or burns do not put the i...

Страница 3: ...ER ACCESSORIES HI 95701 11 CAL CHECK Standard Cuvets 1 set HI 710009 Blue rubber boot HI 710010 Orange rubber boot HI 721310 9V battery 10 pcs HI 731318 Tissue for wiping cuvets 4 pcs HI 731331 Glass...

Страница 4: ...HI 95701 meter measures the free chlorine Cl2 content in water samples in the 0 00 to 5 00 mg L ppm range The method is an adaption of the Standard Method 4500 Cl G for drinking water The reagent is i...

Страница 5: ...a standard solution of 1 00 mg L chlorine and a representative lot of reagent an operator obtained with a single instrument a standard deviation of 0 02 mg L SPECIFICATIONS PRECISION AND ACCURACY 16 C...

Страница 6: ...narrow band interference filters to guarantee both high performance and reliable results HI 95 series block diagram optical layout PRINCIPLE OF OPERATION 15 Turn the meter on by pressing ON OFF When...

Страница 7: ...vet walls with hands Furthermore in order to maintain the same conditions during the zeroing and the measuring phases it is necessary to close the cuvet to prevent any contamination 1 Liquid Crystal D...

Страница 8: ...icons appear above the number of month and day when a date is displayed 4 the blinking Battery icon appears when the battery voltage is getting low 13 MEASUREMENT PROCEDURE Turn the meter on by pressi...

Страница 9: ...bration is selected GUIDE TO DISPLAY CODES 12 It is important that the sample does not contain any debris This would corrupt the reading Each time the cuvet is used the cap must be tightened to the sa...

Страница 10: ...ed thesampleandthezerocuvetareinverted Zero a zero reading was not taken Follow the instruction in the measurement procedure for zeroing the meter 11 The instructions listed below should be carefully...

Отзывы: