background image

7 Bluetooth

7.  BLUETOOTH

With “

PAIr

 

BLU

” or “

On

 

BLU

” selected in Setup, the Bluetooth icon (

&

) will blink for up to 45 seconds, 

indicating the tester is in discoverable mode. Once connected, the icon will stop blinking. If not connected, 
the icon is not displayed.

•  Select “

On 

BLU

”, to enable Bluetooth without bonding.

•  Select “

PAIr 

BLU

”, to enable Bluetooth with bonding. A 6-digit bonding pin is displayed the first 

time the tester and smart device are paired. Once the devices are paired, the bonding pin is not required 

when reconnected. 

•  Select “

OFF 

BLU

”, to disable Bluetooth.

•  Select “

dEL

 

PAIR

”, to delete all paired devices. If PAIr BLU is enabled, a bonding pin will need to 

be re-entered. 

8.  HANNA LAB APPLICATION

•  The Hanna Lab App is available on the App Store

®

 and on Google Play.* 

•  Consult the Help section of the application for information on calibration, measurement, data logging, 

and sharing.

•  When the tester is in discoverable mode, it will appear in the list of “Available Devices”.

•  Within the application, tap “Connect” to pair the tester with the device. All readings are transmitted 

directly to the application.

Tag a Measurement

Once connected to the application, the ON/OFF button can be pressed to tag the current reading. 

•  Press the ON/OFF button from measurement mode. The display shows “

SEt

 

TAG

”, followed by “

-

 

TAG

”. 

•  The reading on the application will flash green and the note icon ( ) will be displayed. Tap the note 

icon ( ) to add an annotation.

&

10.12

25.6

  

&

-

TAG

9.  CALIBRATION

Preparation & Guidelines

1.  Remove the electrode from the plastic storage cap. Save the cap for electrode storage.

2.  Rinse off any storage solution or salts that may be on the body.

3.  Verify there is solution inside the pH bulb by shaking the electrode down to restore continuity as the 

solution may have moved up the stem during shipping.

4.  For best results, use a rinse beaker and a separate calibration beaker for each buffer. Discard rinsing 

buffers after use.

Note

: Remove the blade prior to calibration and clean the electrode.

App Store is a trademark of Apple, Inc.

Google Play and the Google Play logo are trademarks of Google LLC.

Содержание HALO2 HI9810452

Страница 1: ...INSTRUCTION MANUAL Hanna Instruments Inc 584 Park East Drive Woonsocket RI 02895 USA www hannainst com HI9810452 Wireless pH Tester for Meat with built in specialized electrode Foodcare...

Страница 2: ...8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 8 Stand Alone Tester Up to Three Point Calibration 8 With Hanna Lab App Up to Four Point Calibration 8...

Страница 3: ...05 pH mV Range pH mV conversion Resolution 0 1 or 1 mV Temperature Range 0 0 to 60 0 C 32 0 to 140 0 F Resolution 0 1 C 0 1 F Accuracy 0 5 C 0 9 F Calibration Up to three points or four points Automa...

Страница 4: ...e g solvents sodium hypochlorite ultraviolet light and fungal growth the PVDF body has high abrasion resistance and mechanical strength The conical tip allows for easy penetration into solids and sem...

Страница 5: ...nitialization screen displays all LCD segments followed by the battery percentage The tester enters measurement mode Before the tester turns off OFF PWR is displayed briefly Press and hold the ON OFF...

Страница 6: ...ff 8 AOFF 60 AOFF AOFF Calibration Points Option 2P or 3P Press ON OFF button to select between up to two or up to three point calibration 2P CAL 3P CAL Buffer Set Option 7 01 pH Hanna or 6 86 pH NIST...

Страница 7: ...t of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Measurement Once connected to the applicatio...

Страница 8: ...return to measurement mode press the ON OFF button CAL SAVE is displayed briefly With 2P option selected 6 Place the tip of the electrode in the second buffer rinse beaker then in the second calibrat...

Страница 9: ...and improve the pH measurement Note Never immerse the tester over the maximum immersion level Refilling the Electrode To remove the electrode sleeve carefully rotate and slide it off A Set aside Note...

Страница 10: ...r solution 20 mL sachet 25 pcs HI70007P pH 7 01 buffer solution 20 mL sachet 25 pcs HI70009P pH 9 18 buffer solution 20 mL sachet 25 pcs HI70010P pH 10 01 buffer solution 20 mL sachet 25 pcs HI77400P...

Страница 11: ...and maintained according to instructions This warranty is limited to repair or replacement free of charge Damage due to accidents misuse tampering or lack of prescribed maintenance is not covered If...

Страница 12: ...C 12208A 04 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must...

Отзывы: