background image

All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, 

Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA. 

Hanna Instruments reserves the right to modify the design, construction, or appearance of its products without advance notice.

TABLE OF CONTENTS

1.  Preliminary Examination .................................3
2. Specifications .................................................3
3.  General Description & Intended Use .................4

Operating Modes .......................................4
Electrode Features ......................................4

4.  Functional Description & LCD Display ................5
5.  General Operations .........................................5

Turning the Tester On & Off .........................5
Battery Replacement ..................................5

6. Setup ............................................................6

Temperature Unit  ......................................6
Auto-Off Interval ........................................6
Calibration Points .......................................6
Buffer Set ..................................................6
pH Resolution ............................................6

Bluetooth

®

 Wireless Mode ........................6

Bluetooth Pairing .......................................6
Date & Time ..............................................6

7. Bluetooth .......................................................7

8.  Hanna Lab Application ....................................7

Tag a Measurement....................................7

9. Calibration .....................................................7

Preparation & Guidelines ............................7
Procedure ..................................................8
Stand-Alone Tester 
(Up to Three-Point Calibration) ...................8
With Hanna Lab App 
(Up to Four-Point Calibration) .....................8

10.  Care & Maintenance .....................................9

Cleaning ...................................................9
Refilling the Electrode ................................9
Storage .....................................................9

11.  Warning & Error Messages ..........................10
12. Accessories .................................................10
13. Abbreviations .............................................11
Recommendations for Users ................................11
Warranty ..........................................................11
Certification .......................................................12

Dear Customer,

Thank you for choosing a Hanna Instruments

®

 product.

Please read this instruction manual carefully before using this instrument as it provides the necessary 
information for correct use of this instrument as well as a precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail us at 

[email protected]

Visit 

www.hannainst.com

 for more information about Hanna Instruments and our products.

The Bluetooth

®

 word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.

Содержание HALO2 HI9810452

Страница 1: ...INSTRUCTION MANUAL Hanna Instruments Inc 584 Park East Drive Woonsocket RI 02895 USA www hannainst com HI9810452 Wireless pH Tester for Meat with built in specialized electrode Foodcare...

Страница 2: ...8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 8 Stand Alone Tester Up to Three Point Calibration 8 With Hanna Lab App Up to Four Point Calibration 8...

Страница 3: ...05 pH mV Range pH mV conversion Resolution 0 1 or 1 mV Temperature Range 0 0 to 60 0 C 32 0 to 140 0 F Resolution 0 1 C 0 1 F Accuracy 0 5 C 0 9 F Calibration Up to three points or four points Automa...

Страница 4: ...e g solvents sodium hypochlorite ultraviolet light and fungal growth the PVDF body has high abrasion resistance and mechanical strength The conical tip allows for easy penetration into solids and sem...

Страница 5: ...nitialization screen displays all LCD segments followed by the battery percentage The tester enters measurement mode Before the tester turns off OFF PWR is displayed briefly Press and hold the ON OFF...

Страница 6: ...ff 8 AOFF 60 AOFF AOFF Calibration Points Option 2P or 3P Press ON OFF button to select between up to two or up to three point calibration 2P CAL 3P CAL Buffer Set Option 7 01 pH Hanna or 6 86 pH NIST...

Страница 7: ...t of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Measurement Once connected to the applicatio...

Страница 8: ...return to measurement mode press the ON OFF button CAL SAVE is displayed briefly With 2P option selected 6 Place the tip of the electrode in the second buffer rinse beaker then in the second calibrat...

Страница 9: ...and improve the pH measurement Note Never immerse the tester over the maximum immersion level Refilling the Electrode To remove the electrode sleeve carefully rotate and slide it off A Set aside Note...

Страница 10: ...r solution 20 mL sachet 25 pcs HI70007P pH 7 01 buffer solution 20 mL sachet 25 pcs HI70009P pH 9 18 buffer solution 20 mL sachet 25 pcs HI70010P pH 10 01 buffer solution 20 mL sachet 25 pcs HI77400P...

Страница 11: ...and maintained according to instructions This warranty is limited to repair or replacement free of charge Damage due to accidents misuse tampering or lack of prescribed maintenance is not covered If...

Страница 12: ...C 12208A 04 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must...