Hanna Instruments HALO2 HI9810452 Скачать руководство пользователя страница 3

Preliminary Examination

1.  PRELIMINARY EXAMINATION

Remove the tester and accessories from packaging and examine them carefully. For further assistance, please 
contact your local Hanna Instruments office or email us at [email protected].
Each 

HI9810452

 is supplied with a starter kit consisting of:

• pH 4.01 buffer solution, 20 mL (2 sachets)
• pH 7.01 buffer solution, 20 mL (2 sachets)
• Electrode cleaning solution for Meat, Grease, and Fats, 

20 mL (2 sachets)

• Electrode storage solution, 13 mL dropper bottle (1 pc.)
• Gelled bridge electrolyte, 13 mL dropper bottle (1 pc.)
• 3V Lithium battery – CR2032
• Quick reference guide with instrument quality certificate

Designated slot for the meat blade storage. 

FC097

 blade is sold separately.

Note

: Save all packing material until you are sure that the tester works correctly. Any damaged or defective item 

must be returned in its original packing material with the supplied accessories.

2.  SPECIFICATIONS

pH

Range

0.00 to 12.00 pH

Resolution

0.01 or 0.1 pH

Accuracy

±0.05 pH

mV *

Range

pH/mV conversion

Resolution

0.1 or 1 mV

Temperature

Range **

0.0 to 60.0 °C (32.0 to 140.0 °F)

Resolution

0.1 °C; 0.1 °F

Accuracy

±0.5 °C; ±0.9 °F

Calibration

Up to three points or four points *

Automatic buffer recognition with Standard buffers

Hanna (pH 1.68 *, 4.01, 7.01, 10.01) or NIST (pH 1.68 *, 4.01, 6.86, 9.18)

Temperature compensation Automatic (ATC) or Manual (MTC) *

Electrode

Body material

Polyvinylidene Fluoride (PVDF)

Glass

Low Temperature (LT)

Junction

Open

Reference cell

Double, Ag/AgCl

Electrolyte

Gel (refillable)

Tip / Shape

Conic, Ø 5 x 10 mm (Ø 0.19 x 0.39”)

Outer diameter

12 mm (0.47“)

Length

75 mm (2.95”)

Battery type 

3V Lithium – CR2032

Battery life

Approximately 1000 hours (500 hours with Bluetooth enabled)

Environment

0 to 50 °C (32 to 122 °F)

Casing

IP65 ingress protection

Dimensions

51 x 150 x 21 mm (2.0 x 5.9 x 0.8”)

Weight

45 g (1.6 oz.)

* Available with Hanna Lab App

** Measuring outside the recommended operating temperature range may damage the gel electrolyte and void product warranty.

Note

: The tester can display measurements from —2.00 to 16.00 pH. Measurements outside of the pH range will flash. If this happens, assess 

the integrity of the tester and the type of measured sample.

Содержание HALO2 HI9810452

Страница 1: ...INSTRUCTION MANUAL Hanna Instruments Inc 584 Park East Drive Woonsocket RI 02895 USA www hannainst com HI9810452 Wireless pH Tester for Meat with built in specialized electrode Foodcare...

Страница 2: ...8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 8 Stand Alone Tester Up to Three Point Calibration 8 With Hanna Lab App Up to Four Point Calibration 8...

Страница 3: ...05 pH mV Range pH mV conversion Resolution 0 1 or 1 mV Temperature Range 0 0 to 60 0 C 32 0 to 140 0 F Resolution 0 1 C 0 1 F Accuracy 0 5 C 0 9 F Calibration Up to three points or four points Automa...

Страница 4: ...e g solvents sodium hypochlorite ultraviolet light and fungal growth the PVDF body has high abrasion resistance and mechanical strength The conical tip allows for easy penetration into solids and sem...

Страница 5: ...nitialization screen displays all LCD segments followed by the battery percentage The tester enters measurement mode Before the tester turns off OFF PWR is displayed briefly Press and hold the ON OFF...

Страница 6: ...ff 8 AOFF 60 AOFF AOFF Calibration Points Option 2P or 3P Press ON OFF button to select between up to two or up to three point calibration 2P CAL 3P CAL Buffer Set Option 7 01 pH Hanna or 6 86 pH NIST...

Страница 7: ...t of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Measurement Once connected to the applicatio...

Страница 8: ...return to measurement mode press the ON OFF button CAL SAVE is displayed briefly With 2P option selected 6 Place the tip of the electrode in the second buffer rinse beaker then in the second calibrat...

Страница 9: ...and improve the pH measurement Note Never immerse the tester over the maximum immersion level Refilling the Electrode To remove the electrode sleeve carefully rotate and slide it off A Set aside Note...

Страница 10: ...r solution 20 mL sachet 25 pcs HI70007P pH 7 01 buffer solution 20 mL sachet 25 pcs HI70009P pH 9 18 buffer solution 20 mL sachet 25 pcs HI70010P pH 10 01 buffer solution 20 mL sachet 25 pcs HI77400P...

Страница 11: ...and maintained according to instructions This warranty is limited to repair or replacement free of charge Damage due to accidents misuse tampering or lack of prescribed maintenance is not covered If...

Страница 12: ...C 12208A 04 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must...

Отзывы: