HS / HL Valves & Systems Service Manual
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
7
4.
System Installation
Product Dimensions – HS / HL Control Valves
Length (max.)
Width (max.)
Height (max.)
Regeneration Mode
7.5"
4"
7.5"
Down-flow
Inlet Port
Outlet Port
Drain Port
Brine Port
Base
Riser Pipe
3/4"
3/4"
1/2" NPTF
3/8"
2.5"NPSM
1.05"
These valve dimensions are for reference only.
Plumbing Rough-Ins – HS / HL Control Valves
Bypass
Tank
Center to
End of
Bypass
Inlet/
Outlet
Center
Inlet/
Outlet
Height
9x48 Tank
Inlet/
Outlet
Height
10x44 Tank
Inlet/
Outlet
Height
10x54 Tank
Inlet/
Outlet
Height
12x52 Tank
Inlet/
Outlet
Height
13x54 Tank
1" Metal Bypass
5-3/8"
2"
50"
46-5/8"
56-3/4"
54-7/8"
56-7/8"
3/4" Metal Bypass
5-1/4"
2"
50"
46-5/8"
56-3/4"
54-7/8"
56-7/8"
These valve dimensions are for reference only.
Unit Location
•
Locate the filter or softener close to a clean working floor drain away from direct sunlight and any
heat sources. This will minimize consumer impact in the event of malfunction.
•
Ensure the unit is installed with enough space for operation and maintenance.
•
The installation surface should be clean, level and stable for both the pressure tank and brine tank.