HS / HL Valves & Systems Service Manual
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
49
Be sure to shut off any bypass line.
19.
Plug electrical cord into outlet.
20.
Set time of day.
21.
Return the control valve to the In Service position.
22.
Replace the control valve back cover. Be sure grommet at cable hole is in place.
Make sure there is enough brine in the brine tank.
20.
Rotate program wheel counterclockwise until it stops at Regeneration position.
21.
Start regeneration cycle manually if water is hard.
22.
Plug cable into meter cover. Rotate cable to align drive flat if necessary.
Replacing Seals and Spacers
1.
Unplug electrical cord from outlet.
2.
Turn off water supply to system.
3.
Relieve water pressure in the system by putting the valve in the Backwash position momentarily.
4.
Return the valve to the In Service position.
5.
Pull cable out of meter cover.
6.
Remove the valve back cover.
7.
Remove screw and washer at drive yoke.
8.
Remove timer mounting screws. The entire timer assembly should lift off easily.