56
The battery without a dobber
When the electrolyte is above 15-20mm of the
electrode plate, stop replenishing the distilled
water.
–
After replenishing the distilled water, close
the pouring plug and battery cover.
–
Using the damp cloth to clean the surface
of every battery cell.
CAUTION
It is not permitted to overrun the
appointed
tiptop
level
when
replenishing the distilled water.
Adding it too much will result in
leakage of electrolyte, and it will
damage the truck when charging
and discharging..
Draw it out with injector if adding it
too much.
3. Read the specific gravity
–
The specific gravity of the electrolyte
should change follow the temperature.
a. Use
thermometer
to
measure
the
temperature of electrolyte.
b. Put the straw of densimeter into
electrolyte uprightly, extrude rubber tube
with hand and the electrolyte will be
sucked into the glasses tube and then the
floater of the densimeter will float.
c. Numerate the reading of the densimeter.
Notice
:
The dobber of densimeter must rise
uprightly without depending on the glass pipe.
–
Specific gravity measure
Using the densimeter to measure the specific
gravity.
–
Conversion of the specific gravity
The
specific
gravity
at
the
standard
temperature of 30
0
C should be converted as
follow
:
D30= Dt + 0.0007(t - 30)