AUTO: (Smart mode)
(factory default: -2
℃
)
The D2 displays the difference value between the water temperature and the room
temperature. Press the up and down keys to change the set value and set the
temperature deviation range (-5
℃
--+5
℃
), water temperature (D1) range = room
tempe (D2)
±
return difference
value (C1). When the D1 range is not
between C4-C5, the water temperature = upper limit (C5
±
return difference
value
(C1)), or lower limit (C4 +
return difference
value (C1)). For example, setting D2=1
℃
,
Room temperature = 25
℃
, real-time water temperature D1 = 26
℃ ±
return
difference
value (C1), the actual water temperature D1 is controlled between 24.5
and 27.5
℃
.
Regardless of the smart mode or the constant temperature mode, if the water
temperature is lower than (lower limit C4-0.5
℃
), the cooling is no longer performed,
until the water temperature is higher than (lower limit C4+0.5
℃
), then resume
normal control.
If the water temperature is lower than (the set temperature of the heating rod
C6-0.5
℃
), turn on the heating rod; When the water temperature is higher than (the
set temperature of the heating rod C6+0.5
℃
), heating is stopped. (The heating rod
can be equipped as needed, it is not equipped by default)
4.
Setting item parameter codes introduction:
C0: Adjust the alarm difference (5.0-15.0 degrees): In the constant temperature
mode, it indicates that if the difference between the target value and the set value
exceeds the CO value, then the alarm signal is output; in the smart mode: if the
difference between the water temperature and (the room tempe the smart
mode deviation value) is greater than the value of C0, then output an alarm signal.
C1:
return difference
value (0.1
℃
-2.0
℃
, default 1.5
℃
): In the smart mode and
constant temperature mode, the up and down difference value that water
temperature and the target temperature allowed. When this value is too small, the
compressor starts frequently.
C2: Cold water machine system monitoring temperature alarm setting value
(1
℃
-100
℃
): This parameter is set by the factory to default to 60 degrees. Please
contact the factory to modify this parameter.
Содержание HT3200-UV K Series
Страница 1: ...3200 Hybrid UV printer installation instruction HT3200 UV_K...
Страница 16: ...15...
Страница 39: ...38 Select the communication port Select the printer model...
Страница 40: ...39 Select lamp type Browse a path for TopJet...
Страница 42: ...41 Install Click finish to continue...
Страница 43: ...42 Install the driver for PCIE card...
Страница 44: ...43 Accept and click next Continue...
Страница 45: ...44 Finish Normally we do not have to reboot computer after installation 5 2 Topjet software operation guide...
Страница 50: ...49...
Страница 59: ...58 5 2 6 Heads parameter Setting...
Страница 63: ...62 Finish assembly of tube as shown in picture below Left is the outlet tube right is the inlet tube...
Страница 64: ...63 Clean all tubes with flush Connect the tubes with the heads As shown in pictures below...
Страница 65: ...64 Remove the screws on the plate one is at the back side one is at the front side Remove the protective film...
Страница 66: ...65 Put the head to the right position Discharge the protective fluid of the head...
Страница 75: ...74 Modify the page header base point based on the margin...
Страница 110: ...109 Cable diagram of HT3200D head configuration 2X5 Mode DA_YMCKKCMYWW Mode DA_YMCKKCMY_...
Страница 111: ...110 Mode DA_CMYKW Mode DA_ _CMYKW...
Страница 112: ...111 Mode DA_YMCKKCMYWW Mode DS_CMYK...
Страница 113: ...112...