Tension Calibration
The
Tension button on the Diagnostics menu resets the
tension device. Only calibrate the tension device under
the direction of Handi Quilter technical support.
When calibrating the tension, do the following:
1.
Remove the tension knob.
2.
Gently press the spring against the tension discs
while not compressing the spring.
3.
While holding the spring in place, press Reset.
4. When calibration is complete, replace the
tension knob.
Foot Pedal Test
The Pedal test will help determine if there is a problem
with the HQ Capri foot pedal. Slowly depress the foot
pedal, a percent of depression will appear in the white
box. The foot pedal should be controllable from
0 to 100%. Press the
Home button to return to the
Main menu screen or the
Tools button to return to the
Diagnostics menu screen.