US-501 operation manual
US-501 R02 13.07.09 Display version 4, PLC version 4
P.30 of 31
>
Maintenance (cont.)
>> Cutter Self Calibration (cont.)
To initialize self calibration
1.
Press and hold the self calibration button for 2 seconds to initialize the self calibration
sequence.
2.
The actuator system will slowly move the cutter toward the horn face.
3.
At the same time, a pop up screen will appear indicating the status of the self
checking
4.
Do not interfere with the machine during this time including touch screen, switches,
etc.
5.
A noise may appear briefly when the cutter is touching the horn face, this is normal
6.
When the calibration is finished, the pop up screen will disappear and the calibration
is finished. The cutter bit will be retracted to the standby position.
self calibration