US-501 operation manual
US-501 R02 13.07.09 Display version 4, PLC version 4
P.29 of 31
>
Maintenance (cont.)
>> Cutter Self Calibration
Whenever a new cutter bit is installed or other related parts are serviced, due to slight
dimensional variation, the depth of the cutting may have changed. Hence, the machine must
be re-calibrated before the machine can be operated properly.
Check list before the self calibration
1.
The ultrasonic system is in the ‘ready’ status
2.
The cutter bit is securely installed
3.
The cutting edge is aligned properly with the surface of the horn
4.
There is no foreign material such as fabric between the horn face and the cutting bit
Press and hold for 2 seconds to enter the self calibration mode