Appendix D . Tape Start, Tape Middle, Tape End Parameters
> Tape End Program
> Tape End Program > after cut roller speed
This setting controls the sealing speed after the tape is cut. A smaller than normal sealing speed
setting will decrease the sealing speed after tape is cut. A larger than normal sealing speed
setting will increase the sealing speed after tape is cut. This is used to control the heat
absorption of the tape end. Touch the ON/OFF button to enable/disable this function. If this
function is „off‟, the sealing speed does not change after tape is cut.