AI-002 operation manual
Issue 1 21.09.09 display version 13 . main controller version 69 . servo version 61
P.23 of 59
> Start Up and Shut Down Procedures (cont.)
>> Shut down Procedures
1. Disable the heating by pressing the HEAT button if the machine is previously in the
heating mode.
2. Observe the indicated nozzle temperature, the temperature should gradually drop.
3. Wait until the nozzle temperature cool down to 60
C and below, depending on the previous
temperature and surrounding environment, it may take 5-10 minutes.
4. Confirm that the temperature is below 60
C, switch off the machine by pressing the red power
OFF button.
5. Follow by switching off the compressed air by turning the main air ON/OFF switch knob.
WARNING !
Shut down procedures must be followed strictly to avoid damage to the heater. Always
cool down the heater before shutting off the compressed air supply.