LDU 179.1 Technical Manual rev. 1.10 - February 2019 Page 21 of 45
7.
Commands
– Overview
Command Short description
Parameter value
Page
AD
Communication: Device Address
0...255
38
A‘n’
Allocation source for a set point
0, 1 or 2
36
AZ
Absolute zero point calibration
± 33000
28
AG
Absolute gain calibration
± 33000
28
BR
Communication: Baud Rate
9600…460800 baud 39
CE
Calibration: Open Calibration Sequence; Read TAC Counter
0...65535
24
CG
Calibration: Set Calibration Gain (Span) at Load > Zero
1...999999 d
26
CI
Calibration: Minimum Output Value
–999999...0 d
24
CL
Close communication (For compatibility only)
None
CM‘n’
Calibration: Set Maximum Output Value (n = 1, 2 or 3)
0...999999 d
24
CS
Save the Calibration Data (CM, CI, DS, DP, etc.) to the EEPROM
None
28, 40
CZ
Calibration: Set Calibration Zero Point
– Scale Without Load
None
25
DP
Calibration: Set Decimal Point Position
0...5
25
DS
Calibration: Set Display Step Size
1, 2, 5, 10, …, 500 d 25
DT
Trigger function: Calculation Time for Short-time Average
0...65535 ms
43
DX
Communication: Set Full-duplex (1) (For compatibility only)
0…1
39
FD
Factory default settings: Write Data to the EEPROM (TAC protected)
None
26
FM
Digital filter: Filter Mode
0
…1
29
FL
Digital filter: Filter Cut-off Frequency
0...8
30
GA
Output: Get Triggered Average Value
None
33, 41
GG
Output: Get Gross Value
None
32
GI
Retrieves an image file from the LDU
’s EEPROM
None
40
GL
Output: Get Data String “Average/Gross/Status“
None
33
GN
Output: Get Net Value
None
32
GS
Output: Get ADC Sample Value
None
33
GT
Output: Get Tare Value
None
32
GW
Output: Get Data String “Net/Gross/Status“
None
33
H‘n‘
Setpoints: Hysteresis for Setpoint S0 (H0) and S1 (H1)
-9999...+9999 d
36
HT
Trigger function: Hold time for Violation of Setpoint Limit
0...65535 ms
37
ID
Device information: Identify Device
None
23
IN
Logical Input: Input Status
None
35
IO
Logical Output: Output Status
00…11
35
IS
Device information: Identify Device Status
None
23
IV
Device information: Identify Firmware Version
None
23
IZ
Calibration: Correction of System Zero
None
26
MR
Calibration: Define Multi-interval (0) or Multi-range (1)
0 or 1
25
MT
Trigger function: Measuring Time for Averaging
0...3000 ms
41
NA
Network Address (CAN Open address)
1
…127
38
NR
Motion detection: No-motion Range
0...65535 d
29
NS
Network Settings (CAN Interface, Serial channel)
0 …2
38
NT
Motion detection: No-motion Time Period
0...65535 ms
29
OF
Output Format of Data String GL and GW
0…3
33
OM
Output Mask
00…11
35
ON
Open communication and send net weight (For compatibility only)
1…255
OP
Open communication (For compatibility only)
1…255
PI
Download a saved image file to the LDU
’s EEPROM
None
40