3 - 21
Stacked Symbologies
Codablock
< Default All Codablock Settings >
Codablock
Message Length
The message length selection is used to set the valid reading length of the bar
code. If the data length of the scanned bar code doesn’t match the valid reading
length, the scanner will issue an error beep. You may wish to set the same value
for minimum and maximum length to force the scanner to read fixed length bar
code data. This helps reduce the chances of a misread.
EXAMPLE: Decode only those bar codes with a count of 9-20 characters.
Min. length = 09
Max. length = 20
EXAMPLE: Decode only those bar codes with a count of 15 characters.
Min. length = 15
Max. length = 15
A one- to two-digit number and Save are required after reading this
programming symbol. Refer to the Programming Chart (inside back cover).
* Off
On
Maximum
Message Length
Minimum
Message Length
Содержание IMAGETEAM 4400
Страница 4: ......
Страница 12: ...viii ...
Страница 16: ...1 4 IT4700 Imager Identification Enlarged View of Label Hand Held IT4700 Imager Bottom View ...
Страница 110: ...4 8 Exit Selections Save OCR Template Discard OCR Template ...
Страница 116: ...5 6 ...
Страница 146: ...6 30 ...
Страница 152: ...8 4 ...
Страница 158: ...9 6 ...
Страница 164: ...10 6 ...
Страница 168: ...11 4 ...
Страница 175: ......
Страница 178: ...Sample Symbols Aztec Aztec Mesa Code MaxiCode Micro PDF417 Package Label Test Message Test Message Test Message ...
Страница 179: ...Programming Chart 0 2 6 1 7 5 4 3 ...
Страница 180: ...Programming Chart 8 A E 9 F D C B Save Discard E ...
Страница 181: ...Programming Chart OCR a e d l Save Discard c t ...
Страница 182: ...4619 Jordan Road P O Box 187 Skaneateles Falls New York 13153 0187 44 4700 UG Rev H ...