5.1. Electrical Power Terminals
The power terminals of Hanbell compressors are made from ceramic materials and well insulated
more than 1000MΩ. Be careful connecting the wiring and
follow the list below.
⇒
The ceramic part on the power terminal should not be tighten by hitting otherwise the insulation of
the power terminal could be degraded.
⇒
Follow the drawing shown below for the wiring to prevent the power terminal from being damaged.
⇒
The setting of the torque wrench for tightening the copper nut of the terminal bolts should be set less
than 500 kg-cm (36 pound/inch)
The insulation of the ceramic power terminals are
very easily degraded by water, so
DO NOT take
the leakage test by immersing the whole compressor in the water. Shut down the chiller first for
service if the insulation valve of the power terminal is lower than 5MΩ.