User Manual MCx-B-xxxAx-8.09
Page 9 of 10
www.hanbayinc.com | 1 800 315 4461
Rev.2020.3
MCx-B-xxAx
MC
L
-xxxAx
MC
M
-xxxAx
MC
J
-xxxAx
MC
K
-xxxAx models
MC
H
-xxxAx models
Main Dimensions:
Cable Installation:
Select a connection cable with 5 leads.
O.D. 2.5 - 6.5mm (0.10 - 0.26in)
. Be sure to not use a cable with an OD that is no bigger than this!
Remove the liquid
tight fitting from the
actuator casing and
insert the cable into it.
Carefully insert the cable
into the actuator base. Mind
the red motor cable and its
plug into the board. Moving
the plug out of its fully
inserted position may cause
malfunction of the actuator
.
Put the liquid tight fitting
back and tighten (lightly
with tool).
Connect wires according
to your application
(see page 2,3).
The cable has to be stripped
of its jacket for 2 inches
(50mm) and the wires need
1/8” (3mm) stripped ends.
Bend the wires so that
insertion becomes easy.
Hand tighten the liquid tight
fitting to establish seal.
Mount actuator cover
and tighten 4 screws.
1
2
5
4
3
8
7
6