6
Hampton® H35U Direct Vent Freestanding Gas Stove
safety label
This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove. We
have printed a copy of the contents here for
your review.
NOTE: Hampton
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
Copy of Safety Label
920-414
560
560
H35U-NG
H35U-NG
H35U-LP
H35U-LP
C# 4001172
APPAREIL FONCTIONNANT AU GAZ PROPANE
APPAREIL FONCTIONNANT AU GAZ NATUREL
Listed:
VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION
Certified to /Certifié : ANSI Z21.88-2019
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES
AFTER FIRST SALE
Refer to Intertek’s Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
3.5
0.87
1.6
0.40
37
30,000
21,500
(8.78 Kw/h)
(6.30 Kw/h)
Model/Modèle :
Pression d’alimentation minimale
Pression manifold élevée
Pression manifold basse
Débit calorifique maximal
Débit calorifique minimal
Taille de l’orifice
Altitude
Pression d’alimentation minimale
Pression manifold élevée
Pression manifold basse
Débit calorifique maximal
Débit calorifique minimal
Taille de l’orifice
Altitude
11
10
2.74
WC/C.E.
2.49
6.4
1.59
29,500
(8.64 Kw/h)
24,000
7.03
52
Model/Modèle :
ÉLECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE : 115V_60HZ less than/moins de 2 A.
For Use Only with Barrier (Part #743-100). Follow Installation Instructions.
o
Utiliser uniquement avec un écran de sécurité (pièce n 743-100). Suivre les consignes d’installation.
NOT FOR USE WITH SOLID FUELS / NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada / Fabriqué au Canada
utilisé
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
Содержание H35U-NG
Страница 51: ...Hampton H35U Direct Vent Freestanding Gas Stove 51 notes ...
Страница 56: ...56 Hampton H35U Direct Vent Freestanding Gas Stove warranty ...
Страница 57: ...Hampton H35U Direct Vent Freestanding Gas Stove 57 notes ...
Страница 58: ...58 Hampton H35U Direct Vent Freestanding Gas Stove notes ...
Страница 59: ......