Hampton® H35U Direct Vent Freestanding Gas Stove
installation
Offset to Vertical Terminations
Venting Arrangements
Vertical Terminations Systems for Residential Manufactured and Mobile
Homes
The shaded area in the diagram below shows all allowable combinations of straight vertical and
offset to vertical runs with vertical terminations.
Maximum two 45
o
elbows
.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below show
all allowable combinations of vertical runs
with horizontal terminations. Maximum one 90
O
elbow (two 45
o
elbows equal one 90
o
elbow).
All approved caps listed on page 12 - may be
used.
Propane and Natural Gas:
Residential, Manufactured and
Mobile Home Installations
The venting arrangements diagrammed below,
have a min. of 75% (flue loss) efficiency with Fan
Off, as required for manufactured homes. (Actual
efficiency may be as high as 85%)
May be installed in manufactured (mobile)
homes after first sale.
Rotating 45
o
Elbow for Straight Horizontal Terminations
1)
Remove the 4 screws of the top panel.
2)
Remove all 4 screws that secure the elbow to
the unit using a 1/4" magnetic nut driver.
NOTE: See "Vent Restrictor Position" sec-
tion for installation instructions for the Vent
Restrictor Position.
3)
Rotate the elbow 180
o
4)
Secure the elbow by securing it with the 4 screws.
5)
Return top panel. Secure with the four screws.
See figure 1.
Figure 1
Figure 2
Figure 3
Содержание H35U-NG
Страница 51: ...Hampton H35U Direct Vent Freestanding Gas Stove 51 notes ...
Страница 56: ...56 Hampton H35U Direct Vent Freestanding Gas Stove warranty ...
Страница 57: ...Hampton H35U Direct Vent Freestanding Gas Stove 57 notes ...
Страница 58: ...58 Hampton H35U Direct Vent Freestanding Gas Stove notes ...
Страница 59: ......