Connecting to a Network 

If your Temperature Transmitter was not factory-configured to connect to your wireless (Wi-Fi) 
network,  you  will  need  to  perform  this  configuration  step  yourself.    This  section  describes  the 
method used to configure the network connection settings of the Temperature Transmitter. 

Web Configuration Mode 

In  order  to  use  the  Web  Configuration  Mode,  you  will  need  a  wireless  device  such  as  a  laptop 
computer  or  a  smartphone  capable  of  connecting  to  an  IEEE  Standard  802.11B/G  wireless 
network.    Your  wireless  device  must  be  configured  to  obtain  its  IP  address  using  DHCP  (see 
your devices manual, on-line help, or an IT professional for instructions). 
 
If you have installed the three provided AA batteries in your Temperature Transmitter, it will be 
powered  on.    To  enter  the  Web  Configuration  mode  you  must  tap  the  RESET  button.  The 
STATUS  LED  will  illuminate  red 

.    When  this  occurs,  immediately  press-and-hold  the 

DISP/PROG  button  until  the  STATUS  LED  starts  flashing  red  and  green 

.    Release  the 

DISP/PROG button.  When the STATUS LED stops flashing and turns green 

 the sensor is in 

Web Configuration mode. 
 

 

Now,  on  your  wireless  device,  go  to  the  wireless 
network  configuration  and  search  for  new  wireless 
networks.  You should see a network with an SSID 
similar  to  HCC-0B73F2,  where  the  last  six 
characters will be a random sequence containing 0-
9 and A-F.  Connect your device to this network as 
shown in the adjacent image. 

Содержание TT Series

Страница 1: ...ATURE TRANSMITTER OPERATING INSTRUCTIONS HAMPSHIRE CONTROLS CORPORATION PO Box 516 Dover NH 03821 Tel 603 749 9424 Toll free 866 496 9424 Fax 603 749 9433 Please Visit Our Web Site www hampshirecontro...

Страница 2: ...o the repair or replacement at its option of those items which upon examination prove to be defective Such repair or replacement will be made without charge This warranty will be void if repairs or al...

Страница 3: ...r up Sequence 7 Connecting to a Network 8 Web Configuration Mode 8 Operating the Display 12 Min Max Reset 12 Constant Display 12 Alarm Conditions 13 Temperature Alarms 13 Door Switch Alarm Optional 14...

Страница 4: ...m indicator buzzer Display program increment button DISP PROG Mute silence calibrate decrement button MUTE CAL Reset button RESET Throughout this manual you will encounter the following instructions f...

Страница 5: ...4 of 21 2014 Connecting the Antenna Carefully thread the included antenna onto the connector located on the upper left side of the Temperature Transmitter case Tighten the connection with your fingers...

Страница 6: ...iques to prevent room moisture from getting into the cabinet Whenever possible install the probe through an existing access port provided by the cabinet manufacturer then reseal the port Alternatively...

Страница 7: ...eries under normal operating conditions High quality alkaline batteries may be used but with moderately decreased lifetime NOTE The following conditions will shorten battery life RF interference or co...

Страница 8: ...Wi Fi electronics will power up and the unit will try to connect to the network SSID which was entered during the Web Configuration During the connection attempt the STATUS LED will quickly flash gree...

Страница 9: ...its IP address using DHCP see your devices manual on line help or an IT professional for instructions If you have installed the three provided AA batteries in your Temperature Transmitter it will be p...

Страница 10: ...R key or click the GO button The Temperature Transmitter will now serve you its main configuration page which will look like the image shown to the left To configure the wireless network settings on t...

Страница 11: ...n you are finished You will be returned to the main menu Select Set IP Configuration to continue with the network setup On this page you must first select Use static IP After selecting Use Static IP y...

Страница 12: ...15 for more information Select Save Settings when you are done Select Reboot the module from the main menu or tap the RESET button to reboot the Temperature Transmitter Depending on your device optio...

Страница 13: ...ansmission Pressing the DISP PROG button does not cause the sensor to take a new probe temperature reading Min Max Reset The minimum and maximum temperature readings can be reset by pressing and holdi...

Страница 14: ...n is activated The alarm conditions are checked every 3 minutes following each new temperature reading Alarm processing is based on the following flowchart The local temperature alarm is indicated by...

Страница 15: ...zer and 5 red flashes on the STATUS LED repeated every 15 minutes Communication Fault As with any wireless communication system disruptions can sometimes occur The Temperature Transmitter can detect s...

Страница 16: ...on or the MUTE CAL button the current Low Temperature Alarm Limit will be displayed on the LCD To increase the high limit tap the DISP PROG button to decrease the high limit tap the MUTE CAL button Wh...

Страница 17: ...e Door Switch option this value must be set to This indicates that you are about to change the temperature display to either degrees Celsius or degrees Fahrenheit If you tap either the DISP PROG butto...

Страница 18: ...utton tap adjusts the calibration offset by 0 05 C The decimal digit on the LCD may flicker 0 1 C this is within the accuracy limits of the Temperature Transmitter Once you are satisfied with the temp...

Страница 19: ...temperature reading stabilize The decimal digit may flicker 0 1 C When you are satisfied that the reading on the Temperature Transmitter has stabilized press and hold the MUTE CAL button until you hea...

Страница 20: ...ical Case is black ABS plastic 4 w x 4 h x 1 6 d Wall mount with Velcro or set on bottom edge Wires and antenna exit through sides Outputs Wi Fi IEEE Std 802 11b g transmission via UDP IP every 3 minu...

Страница 21: ...lectrical and Electronics Engineers IP Internet Protocol LCD Liquid Crystal Display LED Light Emitting Diode Local alarm An audible or visual indication of an alarm condition by the Temperature Transm...

Страница 22: ...it Updated battery low indication D 5 27 Feb 2014 Updated name and graphics Added additional battery warning Removed WPS section Added min max reset Added display toggle Updated door switch setting te...

Отзывы: