Temperature Transmitter Operating Instruction 

Page 5 of 21 

 

©2014 

Sensor Probe 

The  probe  supplied  with  the  Temperature  Transmitter  is  a  highly  accurate  temperature  sensor.  
The sensor may be put in water or other mild aqueous solutions from 0°C to 100°C. 
 
NOTE:  Avoid  submerging  the  probe  in  solvents  or  harsh  chemicals.    Use  protective  thermo-
wells when monitoring such materials. 
 
NOTE:  The  warranty  does  NOT  cover  damage  to  probes  or  electronics  that  is  caused  by 
exceeding  temperature  limitations,  or  damage  to  probes  caused  by  using  them  in  solvents 
or other unsuitable environments. 
 
NOTE: If the displayed temperature shows a consistent high (> 100°C) or low (< -100°C) value, 
most  likely,  the  probe  has  failed.    The  unit  must  be  returned  for  probe  replacement  and 
recalibration. 

Probe Installation 

The probe may be used in air or in simulated product. 
 
If  installing  the  sensor  in  a  refrigerator,  try  to  place  the  probe  in  a  water  and  glycol  chlorine 
solution to stop bacteria formation. 
 
If  installing  the  sensor  in  a  cabinet  or  enclosure  (particularly  freezers),  make  sure  to  use  good 
techniques to prevent room moisture from getting into the cabinet. Whenever possible, install the 
probe through an existing access port provided by the cabinet manufacturer, then reseal the port. 
 
Alternatively, the probe can be run under, over, or through the door-sealing gasket. Often a door 
gasket will have a joint at one or more corners. Open that joint slightly by carefully making a slit 
with  a  razor  blade.  Insert  the  probe  wire  and  then  reseal  the  joint  with  flexible  silicone  sealing 
compound.  Inside  the  cabinet,  run  the  probe  wire  so  that  it  will  not  become  snagged  during 
loading, unloading or cleaning procedures. 

Probe Location 

Install  the  sensor  probe  in  a  location  where  it  will  respond  to  the  average  temperature  of  the 
space being monitored and not to local conditions caused by door openings, etc. 
 
The object of the probe location is to provide some safety for the area being monitored without 
generating “false” or nuisance alarms. For example, locating the sensor probe on the bottom of a 
chest  freezer  will  result  in  the  alarm  being  sounded  later  than  if  it  was  located  near  the  top. 
However,  locating  the  sensor  too  close  to  the  top  of  the  chest  freezer  could  result  in  the  alarm 
being sounded due to routine lid opening. Choose a probe location that offers the safety desired 
for the enclosure contents. 

Содержание TT Series

Страница 1: ...ATURE TRANSMITTER OPERATING INSTRUCTIONS HAMPSHIRE CONTROLS CORPORATION PO Box 516 Dover NH 03821 Tel 603 749 9424 Toll free 866 496 9424 Fax 603 749 9433 Please Visit Our Web Site www hampshirecontro...

Страница 2: ...o the repair or replacement at its option of those items which upon examination prove to be defective Such repair or replacement will be made without charge This warranty will be void if repairs or al...

Страница 3: ...r up Sequence 7 Connecting to a Network 8 Web Configuration Mode 8 Operating the Display 12 Min Max Reset 12 Constant Display 12 Alarm Conditions 13 Temperature Alarms 13 Door Switch Alarm Optional 14...

Страница 4: ...m indicator buzzer Display program increment button DISP PROG Mute silence calibrate decrement button MUTE CAL Reset button RESET Throughout this manual you will encounter the following instructions f...

Страница 5: ...4 of 21 2014 Connecting the Antenna Carefully thread the included antenna onto the connector located on the upper left side of the Temperature Transmitter case Tighten the connection with your fingers...

Страница 6: ...iques to prevent room moisture from getting into the cabinet Whenever possible install the probe through an existing access port provided by the cabinet manufacturer then reseal the port Alternatively...

Страница 7: ...eries under normal operating conditions High quality alkaline batteries may be used but with moderately decreased lifetime NOTE The following conditions will shorten battery life RF interference or co...

Страница 8: ...Wi Fi electronics will power up and the unit will try to connect to the network SSID which was entered during the Web Configuration During the connection attempt the STATUS LED will quickly flash gree...

Страница 9: ...its IP address using DHCP see your devices manual on line help or an IT professional for instructions If you have installed the three provided AA batteries in your Temperature Transmitter it will be p...

Страница 10: ...R key or click the GO button The Temperature Transmitter will now serve you its main configuration page which will look like the image shown to the left To configure the wireless network settings on t...

Страница 11: ...n you are finished You will be returned to the main menu Select Set IP Configuration to continue with the network setup On this page you must first select Use static IP After selecting Use Static IP y...

Страница 12: ...15 for more information Select Save Settings when you are done Select Reboot the module from the main menu or tap the RESET button to reboot the Temperature Transmitter Depending on your device optio...

Страница 13: ...ansmission Pressing the DISP PROG button does not cause the sensor to take a new probe temperature reading Min Max Reset The minimum and maximum temperature readings can be reset by pressing and holdi...

Страница 14: ...n is activated The alarm conditions are checked every 3 minutes following each new temperature reading Alarm processing is based on the following flowchart The local temperature alarm is indicated by...

Страница 15: ...zer and 5 red flashes on the STATUS LED repeated every 15 minutes Communication Fault As with any wireless communication system disruptions can sometimes occur The Temperature Transmitter can detect s...

Страница 16: ...on or the MUTE CAL button the current Low Temperature Alarm Limit will be displayed on the LCD To increase the high limit tap the DISP PROG button to decrease the high limit tap the MUTE CAL button Wh...

Страница 17: ...e Door Switch option this value must be set to This indicates that you are about to change the temperature display to either degrees Celsius or degrees Fahrenheit If you tap either the DISP PROG butto...

Страница 18: ...utton tap adjusts the calibration offset by 0 05 C The decimal digit on the LCD may flicker 0 1 C this is within the accuracy limits of the Temperature Transmitter Once you are satisfied with the temp...

Страница 19: ...temperature reading stabilize The decimal digit may flicker 0 1 C When you are satisfied that the reading on the Temperature Transmitter has stabilized press and hold the MUTE CAL button until you hea...

Страница 20: ...ical Case is black ABS plastic 4 w x 4 h x 1 6 d Wall mount with Velcro or set on bottom edge Wires and antenna exit through sides Outputs Wi Fi IEEE Std 802 11b g transmission via UDP IP every 3 minu...

Страница 21: ...lectrical and Electronics Engineers IP Internet Protocol LCD Liquid Crystal Display LED Light Emitting Diode Local alarm An audible or visual indication of an alarm condition by the Temperature Transm...

Страница 22: ...it Updated battery low indication D 5 27 Feb 2014 Updated name and graphics Added additional battery warning Removed WPS section Added min max reset Added display toggle Updated door switch setting te...

Отзывы: