Display function – “
advanced menu
” - submenu “General Sets”
The “
General sets
” submenu allows to enter the machine general parameters. “
General sets
” is
very similar to “
user menu
”.
General Sets:
default
Language setup for the text
interface of the machine.
Language: ###
IT
General Sets:
default
Machine model setup (with or
without dosing system).
Model: ###
ANTEA
General Sets:
default
Setup for installed battery types.
Battery: ###
GEL
General Sets:
default
Reset for partial hour meter (as in
the “
user menu
”).
Rst.Cnthr: ###
N
General Sets:
default
Reset for general hour meter
(key, brush, vacuum, traction).
Rst.Main Cnthr: ###
N
General Sets:
default
Hourmeter mode:
key
– connected to ON/OFF key.
Traction
– connected to traction
motor.
Display Cnt: ###
TRACTION
General Sets:
default
Display tune
Display tune: ###
15
General Sets:
default
Display brightness
Display brightness: ###
0