ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
2 of 25
Display function – Alarm Table
The display shows the possible alarms of the machine.
Alarms are shown on the first line of the display and it alternates between the alarm id and a
short alarm description.
Here below the alarm table.
Allarm id.
Alarm Description
What to do
AL_1: Function
Brushes Current
Protection
High current consumption detected. Check
the brush motor absorption and utilization.
Brushes Ammeter
AL_2: Function
Vacuum Current
Protection
High current consumption detected. Check
the
vacuum
motor
absorption
and
utilization.
Vacuum Ammeter
AL_3: Function
Damaged powerstage
Brush or vacuum power stage damaged.
Replace the electronic card.
Powerstage Fail
AL_4: Function
Brush or Vacuum
overcurrent
Short circuit on brush or vacuum motor
output. Check motor cables and conditions.
Overcurrent
AL_5: Function
Thermal protection on
brush or vacuum
motor
Over temperature on brush or vacuum
stage. Wait 5 minutes and check the motor
absorption rate.
Overtemperature
AL_10: Function
Batteries not
connected
Check the connections of the batteries
cables and the related connections on the
electronic card.
Batt. Connection
AL_13: Traction
Lever fault
Check connections and functionality of
potentiometer.
Lever Failure
AL_14: Traction
Pressed lever during
turning on
Forward Micro Switch pressed at turning on.
Release the lever.
Release lever
AL_15: Traction
Thermal protection on
traction motor
Over temperature on traction stage. Wait 5
minutes and check the motor absorption.
Overtemperature
AL_16: Traction
Damaged powerstage
Traction power stage damaged. Replace
the electronic card.
Powerstage fail
AL_17: Traction
Traction overcurrent
Short circuit on traction motor output.
Check motor cables and conditions.
Overcurrent