ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
12 of 25
Display function – “
advanced menu
” - submenu “Vacuum Sets”
The “
Vacuum sets
” submenu allows to enter the parameters and settings related to vacuum
motor.
Vacuum Sets:
default
Maximum current provided from the
electronic card to the vacuum motor.
Max motor current: ##[A]
40
Vacuum Sets:
default
Nominal current, joined with T_Nom
define the condition of
Vacuum Current
Protection
. (alarm + cut off of the
motor).
Nom. motor current: ##[A]
22
Vacuum Sets:
default
Nominal timer, joined with I_Nom define
the
condition
of
Vacuum
Current
Protection. (alarm + cut off of the
motor).
Nom. motor time:
##[s]
30
Vacuum Sets:
default
Delay in turning off the vacuum motor at
the lifting of squeegee body lever.
Switch off delay:
##[s]
5
Vacuum Sets:
default
Not used.
Reset delay:
##[s]
15
Vacuum Sets:
default
Voltage reduction for vacuum motor in
ECO mode.
Ecomode voltage: ###[V]
17
Press the “key 2” to exit the submenu.
Press the “key 2” to go back to the working mode.