18
Saw-Spindle Moulder
B3 / B3 e-classic
Circular saw drive / Spindle moulder unit
Alternating-current motor Three-phase current motor
Motor voltage
1x 230 V
3x 230 V / 3x 400 V
motor frequency
50/60 Hz
50/60 Hz
System of protection
IP 55
IP 55
B3 Perform
Motor power S6-40 %*)
-
4 kW
Motor power S6-40 % - Option*)
3 kW
4 kW
B3 Winner/Winner comfort
Motor power S6-40 %*)
-
3 kW (3x 400 V)
Motor power S6-40 % - Option*)
3 kW
4 kW (3x 400 V)
B3 e-classic
Motor power S6-40 %*)
-
3 kW (3x 400 V)
Motor power S6-40 % - Option*)
3 kW
-
Antriebsmotor Vorritzeinheit (Option)
Motor power S6-40 %*)
0,65 kW**)
0,65 kW
*) S6 = operation under load and intermittent service; 40% = relative operating factor
**) Max. cutting height: 2 mm
mains voltage according to specification plate
±10%
Safeguarding
see circuit plan
Power supply cord (H07RN-F)
3x2,5 mm²/ 5x2,5 mm²
Triggering characteristic
C (D*)
*) if starting up is slow, caused by large swinging masses
Specifications
4.2 Operation and storage conditions
Operating/room temperature
+10° to +40°C
Storage temperature
–10° to +50 °C
4.3 Electrical connection
4.4 Drive motor
The actual values can be found on the data plate.