75
A2-26
Maintenance
Alternatively, machines without a separate feed motor can be
equipped with red
[Stop] buttons instead of the [Emergency Stop]
buttons.
Carry out emergency stop test with all red
[Stop]
buttons on the
machine.
Test the emergency stop if the machine is equipped with an
[emergency stop] button
1.
Prepare the machine to operate.
2.
Switch machine on.
3.
Push the
[Emergency stop]
.
Machine will stop immediately.
●
Continue with next step.
Machine does not stop immediately.
●
If present: Switch off
[Main switch]
(position
"O" / "OFF"
).
●
Disconnect the machine from the mains power supply.
●
Contact Felder Group-service.
4.
Switch the machine on using the green
[start]
button with the
[emergency
stop]
button locked.
machine does not start.
●
Unlock the
[Emergency stop]
button by turning it.
●
Repeat with all
[Emergency Stop]
buttons on the machine.
Machine can not be started.
●
Press the red
[Stop]
button.
●
If present: Turn the
[main switch]
off (position
"O" / OFF
) and secure
it.
●
Contact Felder Group-service.
Test the red stop button as the emergency stop if the machine is not equipped with an
[emergency stop] button
1.
Prepare the machine to operate.
2.
Switch machine on.
3.
Press the red
[Stop]
button.
Machine will stop immediately.
●
Repeat the test on the next red
[Stop]
button.
●
Repeat with all red
[Stop]
buttons on the machine.
Machine does not stop immediately.
●
If present: Switch off
[Main switch]
(position
"O" / "OFF"
).
●
Disconnect the machine from the mains power supply.
●
Contact Felder Group-service.
Содержание A2-26
Страница 6: ...6 Table of contents 12 3 Spare parts list 86 12 4 Circuit diagram 92 ...
Страница 67: ...67 A2 26 Maintenance 10 Maintenance ...
Страница 92: ...92 Attachment 12 4 Circuit diagram ...
Страница 93: ......