![Hammer A2-26 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/hammer/a2-26/a2-26_operating-instructions-manual_3450113021.webp)
21
A2-26
Technical information
4.2
Operation and storage conditions
Data
Value Unit
Operating/room temperature
+5 - +40 °C
Storage temperature
-10 - +50 °C
Humidity (non-wetting)
90 %
4.3
Electrical connection
Data
Value Unit
Mains voltage according to specifica-
tion plate
±10 %
Frequency according to data plate
50 / 60 Hz
Power supply cable 1 x 230 V (H07
RN-F)
3 x 1.5 mm²
Fuse protection
see the wiring
diagram
Triggering characteristic
C
4.4
Drive motor
The actual values can be found on the machine nameplate on the components.
Alternating-current motor
Data
Value Unit
Motor voltage (standard)
1 x 230 V V
Motor frequency
50 / 60 Hz
Protection class
IP 54
Motor power S6
1.9 kW
4.5
Planing unit
The machine is equipped with a machine specific, marked cutterblock,
●
which has a permissible maximum rotation speed that is higher than the
maximum possible rotation speed of the machine.
●
which complies with the standard DIN EN 847-1:2013.
●
which is marked with "MAN".