![Hamilton XE Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/hamilton/xe/xe_operational-manual_585032005.webp)
Document #101-0079
5
11/30/17
DIP SWITCH SETTINGS
Switch #
OFF
ON
1
Normal Operating Mode
Diagnostic Mode
2
Accept Tokenotes
®
Reject Tokenotes
®
3
Controller Runs Stacker
Validator Runs Stacker
4
Not Using Dual Stacker
Dual Stacker Being Used
5
Accepts in Both Directions
Black Seal First
6
For HOPPER type machines
# of $1 RELAY pulses - 1 for $1
# of $5 RELAY pulses - 1 for $5
2 for $10
4 for $20
For TUBE type machines # of
$1 RELAY pulses.
1 pulse per dollar.
7
Accept $1
Reject $1
8
Accept $5
Reject $5
9
Accept $10
Reject $10
10
Accept $20
Reject $20
When programming Tokenotes
®
with the XE, all switches need to be set to the “ON” position. The switches
should be turned “ON” from BOTTOM to TOP, starting with switch #10.
When programming is complete, the switches should be turned “OFF” from TOP to BOTTOM, starting with
switch #1. This will prevent accidental entry into any diagnostic modes. It is possible to get error codes and
total reject by entering certain diagnostic modes. Cycling power will clear this diagnostic mode.
Switch #1:
Switch #1 should ALWAYS be in the OFF position. The validator will not function properly
otherwise.
Switch #2:
Switch #2 should be in the ON position unless the new Hamilton Tokenotes
®
are being
used. If they are being used, this switch should be moved to the OFF position.
When the #2 switch is ON, the validator rejects Tokenotes
®
already programmed in.
Switch #3:
Switch #3 selects the source of stacker control signals when operating in pulse
communications mode. In serial communications mode, this switch is ignored. In nearly
all situations, this switch should be set to off.
Switch #4:
Switch #4 should be in the OFF position unless the Hamilton Dual Stacker is being
used.
II. SWITCH SETTINGS