Mechanical Installation
Remove HTK from the shipping pallet/skid
HTK is securely mounted to the pallet/skid with four (4) mounting bolts and nuts. With the main door open,
unlock the vault door inside.
Loosen and remove the two nuts from the bolts inside the vault area. Repeat this process on the two bolts
next to the power supply. Once this process is complete, you will be able to remove HTK from the pallet/skid.
Positioning
There are no set guidelines for the placement of HTK. However, it is recommended that the machine is
positioned far enough away from the wash entrance to minimize the amount of over spray that may reach
the unit.
The recommended height from the pavement to the bottom of the HTK cabinet is approximately 24” - this
ensures customers in most vehicle types can interact with HTK without excessive overreach.
Mounting
HTK must be securely mounted by using one of the following methods:
BRICK MOUNTING
Uses a custom-built brick or concrete enclosure to house HTK
. See Figures 2.1 - 2.4 on pages 8 & 9 for
mounting hole locations.
HTK provides for six (6) 5/8” mounting holes. Have your engineer or contractor
recommend a construction method suitable for strength and stability.
BASE MOUNTING
This method involves mounting HTK on an optional base. The base is secured to the pavement or curb,
and HTK is then secured to the base. The type of fasteners used should be recommended by your engineer
as to strength and suitability.
Running Conduit
Typical electrical code requires low and high voltage wiring to be run in separate conduits. HTK has three
(3) 1-1/8” conduit mounting holes in the back of the cabinet (brick-in only), as well as six (6) 1-1/8” conduit
holes in the bottom of the cabinet.
• Conduit carrying high voltage 120VAC power lines should be connected to either of the bottom two
right conduit holes, or the one back right conduit hole (as viewed from the front of the machine).
These conduits are designated only for 110v for the power supply.
• Conduit carrying lines with 24VAC, 24VDC, 12VAC or 12VDC signals should be connected to
either
one of the four bottom-left conduit holes, or either one of the back-left conduit holes.
• External communication lines (Cat 5 or Cat 5E, Video, POS etc.) should be run through separate
conduit and connected to any of the open conduit holes on either the bottom-left or back-left of HTK.
NOTE: free-standing cabinets do not have conduit holes in the back.
Содержание HTK Pay Station
Страница 10: ...HTK INSTALLATION MANUAL 10 Mechanical Installation Figure 2 5 Door ...
Страница 22: ...HTK INSTALLATION MANUAL 22 Figure 7 4 Gated Sequence Software Ether Vend MIB Gate Electrical Installation ...
Страница 28: ...HTK INSTALLATION MANUAL 28 Component Connections Figure 8 4 Gen3 controller connections ...
Страница 29: ...HTK INSTALLATION MANUAL 29 Distribution Board Figure 8 5 Distribution board connections Component Connections ...
Страница 30: ...HTK INSTALLATION MANUAL 30 Component Connections Smart Bus Hub Figure 8 6 Smart Bus Hub connections ...
Страница 31: ...HTK INSTALLATION MANUAL 31 Component Connections Bill Dispenser Figure 8 7 Bill dispenser connections ...
Страница 32: ...HTK INSTALLATION MANUAL 32 Component Connections Stacker Interface Figure 8 8 Stacker interface connections ...