Electrical Installation
Electrical Installation
HTK operates on
120 VAC, 60 Hz
with a Constant Voltage Transformer (CVT). This unit must be hard-wired
with conduit, and requires a dedicated power source. Under no circumstances should additional equipment
be operating off the dedicated power source for HTK.
If a dedicated power source is unavailable, cease installation until one is established.
Pulling Wires
The number of wires that must be pulled for HTK are shown in the table below:
THREE (3) WIRES
Electrical power (Hot, Neutral, and Ground)
NINE (9) WIRES
Eight (8) for washes
*
, one (1) common
TWO (2) WIRES
Cycle inhibit
TWO (2) WIRES
Optional
Wash in Service (WIS)
TWO (2) WIRES
Out of Service relay
SPARE WIRES
For future options
TWO (2) CONDUCTOR TWISTED SHIELDED CABLE
Optional
Hamilton Code System / POS 4000
CAT5
Credit Card, Gift Card, and Hosted Solutions
Shielded Video Cable
Video/Camera
*
The Wash Interface supports up to eight (8) washes. If only offering four washes, you may pull five (5) wires instead of nine (9)
(four (4) for washes, one (1) common)
For proper operation of HTK, the wires listed above must be pulled and terminated as
explained on the following pages.
CAUTION! TO AVOID SEVERE INJURY OR DEATH, ALWAYS DISCONNECT
POWER TO THE MACHINE WHILE SERVICING. ALL ELECTRICAL WORK
MUST BE PERFORMED BY A QUALIFIED ELECTRICAL CONTRACTOR.
Содержание HTK Pay Station
Страница 10: ...HTK INSTALLATION MANUAL 10 Mechanical Installation Figure 2 5 Door ...
Страница 22: ...HTK INSTALLATION MANUAL 22 Figure 7 4 Gated Sequence Software Ether Vend MIB Gate Electrical Installation ...
Страница 28: ...HTK INSTALLATION MANUAL 28 Component Connections Figure 8 4 Gen3 controller connections ...
Страница 29: ...HTK INSTALLATION MANUAL 29 Distribution Board Figure 8 5 Distribution board connections Component Connections ...
Страница 30: ...HTK INSTALLATION MANUAL 30 Component Connections Smart Bus Hub Figure 8 6 Smart Bus Hub connections ...
Страница 31: ...HTK INSTALLATION MANUAL 31 Component Connections Bill Dispenser Figure 8 7 Bill dispenser connections ...
Страница 32: ...HTK INSTALLATION MANUAL 32 Component Connections Stacker Interface Figure 8 8 Stacker interface connections ...